Hazard search

Dichlorotetrafluoroethane

CAS number
76-14-2
Also known as
1,2-Dichlorotetrafluoroethane · 1,2-Dichlorotetrafluoroethane (Freon 114) · Cryofluorane · Cryofluorane (INN) · Freon 114 · Freon 114 (1,2-dichlorotetrafluoroethane)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 1000 ppm
8-hour TWA 7110 mg/m³
15-minute STEL 1250 ppm
15-minute STEL 8890 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 88
VOCs in air by GC-FID
Method document (opens in a new tab)
Passive Passive Sampler 575-001
MDHS 96
VOCs in air by GC-FID
Method document (opens in a new tab)
Active (pump) Two charcoal tubes in series (front 400/200 mg, back 100/50 mg) GC-FID 226-09
226-01
NIOSH 1018
1,2-Dichlorotetrafluoroethane by GC-FID
Method document (opens in a new tab)
Active (pump) Two charcoal tubes in series (front 400/200mg, back 100/50mg) GC-FID 226-09
226-01
ASTM D 5466 GC-MS
Non-agency
1,2-Dichlorotetrafluoroethane by Colorimetric analysis
Direct-reading Gastec Pyrotec tube 810-51
Non-agency
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Passive sampler 575-001
575-002
Other Passive GC-FID 575-001
575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.