Hazard search

Copper (fume)

CAS number
7440-50-8
Also known as
Copper (Elements by Cellulosic Internal Capsule Sampler) · Copper (Elements by ICP Aqua Regia Ashing) · Copper (Elements by ICP HNO3 Digestion) · Copper (Elements by ICP HNO3/HClO4 Ashing) · Copper dust · Copper dust & mists (as Cu) · Copper dusts & mists · Copper dusts & mists (as Cu) · Copper fume (ICP analysis of metal/metalloid particulates from solder operations) · Cu

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.02 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter XRF 225-70A
225-1930
NIOSH 7029
Copper (dust and fume) by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in preloaded cassette AA-F 225-3-01
225-1
NIOSH 7300
Elements by ICP (Nitric/perchloric acid ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
225-8408
NIOSH 7301
Elements by ICP (Aqua regia ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter or 5µm PVC filter in 37mm cassette ICP-AES 225-3-01
225-803
225-1
NIOSH 7303
Elements by ICP HNO3 Digestion
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
NIOSH 7306 Active (pump) ICP-AES 225-8517
225-1
NIOSH 9102
Elements on wipes by ICP -AES
Method document (opens in a new tab)
Surface Wipe 225-2414
OSHA 206
Metal & metalloid particulates from solder operations by ICP
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette 225-3-01
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
OSHA ID 206 Active (pump) ICP-AES 225-3-01
225-1
225-2413
OSHA ID-121
Metal & metalloid particulates by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in preloaded cassette 225-3-01
225-1
OSHA ID-125G
Metals & metalloid particulates by ICP
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 25mm or 37mm cassette 225-3100
225-3-01
225-1
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)