Hazard search

Cobalt

CAS number
7440-48-4
Also known as
Co · Cobalt & cobalt compounds (as Co) · Cobalt & compounds (as Co) · Cobalt (Elements by Cellulosic Internal Capsule Sampler) · Cobalt (Elements by ICP Aqua Regia Ashing) · Cobalt (Elements by ICP HNO3 Digestion) · Cobalt (Elements by ICP HNO3/HClO4 Ashing) · Cobalt (Elements on Wipes) · Cobalt metal, dust & fume · Cobalt metal, dust & fume (as Co)

UK workplace exposure limits

Our data hold no UK limit for this substance.

Notations

  • Carc: carcinogen
  • Sen: can cause sensitisation

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter XRF 225-70A
225-1930
NIOSH 7027
Cobalt & compounds by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in preloaded cassette (or Solu-CAP cassette) AA-F 225-3-01
225-8517
225-1
NIOSH 7300
Elements by ICP (Nitric/perchloric acid ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette (or Solu-CAP cassette) ICP-AES 225-3-01
225-8517
225-1
NIOSH 7301
Elements by ICP (Aqua regia ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter (or Solu-CAP cassette) or 5µm PVC filter in 37mm cassette ICP-AES 225-3-01
225-8517
225-803
225-1
NIOSH 7303
Elements by ICP HNO3 Digestion
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
NIOSH 7306
Elements by Cellulosic Internal Capsule Sampler ICP -AES
Method document (opens in a new tab)
Active (pump) Solu-CAP MCE Filters Preloaded in Cassettes and Cassette Holder ICP-AES 225-8517
225-1
NIOSH 9102
Elements on wipes by ICP -AES
Method document (opens in a new tab)
Surface Wipe ICP-AES 225-2414
225-2415
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
OSHA ID 213 Active (pump) ICP-AES 225-3-01
225-1
225-24
OSHA ID-121
Metal & metalloid particulates by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in preloaded cassette 225-3-01
225-1
OSHA ID-125G
Metals & metalloid particulates by ICP
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 25mm or 37mm cassette 225-3100
225-3-01
225-1
OSHA ID-213
Tungsten & Cobalt by ICP -AES
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette 225-3-01
225-1
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)