Hazard search

Calcium oxide - inhalable fraction

CAS number
1305-78-8
Also known as
Calcium oxide · Calcium oxide (calcium) · Calcium oxide (Elements by ICP HNO3 Digestion) · Calcium oxide - respirable fraction · Lime · Quicklime

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 2 mg/m³ Calcium oxide - inhalable fraction
8-hour TWA 1 mg/m³ Calcium oxide - respirable fraction
15-minute STEL 4 mg/m³ Calcium oxide - respirable fraction

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (total inhalable)
Method document (opens in a new tab)
Active (pump) IOM sampler 225-70A
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (respirable)
Method document (opens in a new tab)
Active (pump) IOM sampler & foam, or cyclone 225-70A
225-772
225-69
NIOSH 7020
CALCIUM and compounds, as Ca by AA-F
Method document (opens in a new tab)
Active (pump) Filter Cassette AA-F 225-3-01
225-1
225-3100
NIOSH 7303
Elements by ICP (Hot block/HCl/HNO3 Digestion)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID-121
Metal & metalloid particulates in Workplace Atmospheres by AA/AES
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-1
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter and foam 225-70A
225-1930
225-772

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)