Hazard search

Cadmium oxide

CAS number
1306-19-0
Also known as
Cadmium monoxide · Cadmium oxide fume (as Cd)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.025 mg/m³
15-minute STEL 0.05 mg/m³

Notations

  • Carc: carcinogen

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter XRF 225-70A
225-19
225-1930
NIOSH 7048
Cadmium & compounds by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette AA-F 225-3-01
225-1
ISO 10882-1: 2011
Welding fumes by gravimetric or chemical analysis
Method document (opens in a new tab)
Active (pump) Headset & minisampler with 13mm MCE filter 225-6200
225-6201
225-6202
225-8050

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)