Hazard search

Acrylonitrile

CAS number
107-13-1
Also known as
2-Propenenitrile · Acrylonitrile (Vinyl Cyanide) · Cyanoethylene · Vinyl cyanide

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 2 ppm
8-hour TWA 4.4 mg/m³

Notations

  • Carc: carcinogen
  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 88
VOCs by solvent extraction and GC-FID
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96 Active (pump) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
NIOSH 1604
Acrylonitrile by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 37
Acrylonitrile by GC-NPD
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-NPD 226-01
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes TD, GC 226-350
226-347
224-26-02
224-26-CPC
Non-agency
Acrylonitrile by Colorimetric analysis
Direct-reading Gastec detector tube 810-191
810-191L
810-102L
Non-agency
VOCs by solvent extraction and GC-FID
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by solvent desorption and TD,GC
Method document (opens in a new tab)
Passive Anasorb GCB1 (370 mg) passive sampler 690-101
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)