Hazard search

5-Methyl-3-heptanone

CAS number
541-85-5
Also known as
5-Methyl-3-heptanone (ketones II) · 5-Methyl-3-heptanone (see online Passive Sampling Guide) · 5-methylheptan-3-one · 5-Methylheptane-3-one · Ethyl amyl ketone · Ethyl sec-amyl ketone

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 10 ppm
8-hour TWA 53 mg/m³
15-minute STEL 20 ppm
15-minute STEL 107 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-002
575-001
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
NIOSH 1301
Ketones by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 2553
Ketones by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb CMS tube (150/75mg) GC-FID
Non-agency
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Passive sampler 575-001
575-002
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.