Hazard search

1,2-Dichloroethylene cis:trans isomers 60:40

CAS number
540-59-0
Also known as
1,2-Dichloroethene · 1,2-Dichloroethylene (1,2-dichloroethene) · 1,2-Dichloroethylene (hydrocarbons, halogenated) · Acetylene dichloride · sym-Dichloroethylene · symmetrical Dichloroethylene

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 200 ppm
8-hour TWA 806 mg/m³
15-minute STEL 250 ppm
15-minute STEL 1010 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 88
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Anasorb CSC (350 mg) or Anasorb® 747 (500 mg) passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
NIOSH 1003
Halogenated hydrocarbons by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
Non-agency
1,2-Dichloroethylene by Colorimetric analysis
Direct-reading Gastec detector tube 810-139
810-132HA
810-132LL
Non-agency
1,2-Dichloroethylene by Colorimetric analysis
Passive Gastec Dosi-tube 810-174D
810-132D
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive DR 810-132D
Other Passive DR 810-174D

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)