Hazard search
1,2-Dichloroethane
- CAS number
- 107-06-2
- Also known as
- 1,2-Dichloroethane (ethylene dichloride) · 1,2-Ethylene dichloride · Ethylene chloride · Ethylene dichloride · Ethylene dichloride (1,2-dichloroethane) · Ethylene dichloride (1,2-dichloroethane) (hydrocarbons, halogenated)
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 5 ppm | |
| 8-hour TWA | 21 mg/m³ |
Notations
- Carc: carcinogen
- Sk: can be absorbed through the skin
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 72 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube | TD, GC | 226-357 226-358 |
| MDHS 80 | Active (pump) | TD, GC | 226-358 | |
| MDHS 88 VOCs by solvent desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-001 |
| MDHS 96 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| MDHS 104 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | 226-01 | |
| MDHS 104 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Chromosorb 106 TD tube (300mg) | 226-358 | |
| NIOSH 1003 Hydrocarbons (halogenated) by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| OSHA 03 Ethylene dichloride by GC-ECD Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-ECD | 226-01GWS |
| EPA TO-17 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Two Thermal Desorption tubes | TD, GC | 226-350 226-347 224-26-02 224-26-CPC |
| Non-agency Ethylene dichloride by Colorimetric analysis | Direct-reading | Gastec detector tube | 810-135 810-135L 810-232 | |
| Non-agency VOCs by solvent extraction and GC Method document (opens in a new tab) | Passive | Anasorb CSC (500mg) passive sampler | 690-105 | |
| Non-agency VOCs by thermal desorption and GC Method document (opens in a new tab) | Passive | Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) passive sampler | 690-101 690-103 | |
| Other | Passive | GC-FID | 575-001 | |
| Other | Passive | GC-FID | 575-002 | |
| Other | Passive | TD, GC | 690-101 690-103 | |
| Other | Passive | GC-FID | 690-105 | |
| Other | Passive | DR | 810-174D | |
| Other Internal | Passive | TD, GC | 690-101 690-103 | |
| Other Internal | Passive | GC-FID | 690-105 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)