Hazard search

1,2-Dichloroethane

CAS number
107-06-2
Also known as
1,2-Dichloroethane (ethylene dichloride) · 1,2-Ethylene dichloride · Ethylene chloride · Ethylene dichloride · Ethylene dichloride (1,2-dichloroethane) · Ethylene dichloride (1,2-dichloroethane) (hydrocarbons, halogenated)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 5 ppm
8-hour TWA 21 mg/m³

Notations

  • Carc: carcinogen
  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube TD, GC 226-357
226-358
MDHS 80 Active (pump) TD, GC 226-358
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Chromosorb 106 TD tube (300mg) 226-358
NIOSH 1003
Hydrocarbons (halogenated) by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 03
Ethylene dichloride by GC-ECD
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-ECD 226-01GWS
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes TD, GC 226-350
226-347
224-26-02
224-26-CPC
Non-agency
Ethylene dichloride by Colorimetric analysis
Direct-reading Gastec detector tube 810-135
810-135L
810-232
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) passive sampler 690-101
690-103
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
690-103
Other Passive GC-FID 690-105
Other Passive DR 810-174D
Other Internal Passive TD, GC 690-101
690-103
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)