Hazard search

1,1,2,2-Tetrachloroethane

CAS number
79-34-5
Also known as
1,1,2,2-Tetrachloroethane (see online Passive Sampling Guide) · 1,1-Dichloro-2-2,dichloroethane · Acetylene tetrachloride · sym-Tetrachloroethane

UK workplace exposure limits

Our data hold no UK limit for this substance.

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax thermal desorption tube (250mg) 226-357
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
MDHS 96 Active (pump) GC-FID 226-01
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Anasorb 747 tube (140/170mg) 226-81A
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 1019
1,1,2,2-Tetrachloroethane by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb 747 tube (140/70mg) GC-FID 226-81A
NIOSH 2562
1,1,2,2-Tetrachloroethane by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb CMS tube (100/50mg) GC-FID
ASTM D 5466 GC-MS
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes TD, GC 226-350
226-347
224-26-02
224-26-CPC
Non-agency
Tetrachloroethane by Colorimetric analysis
Method document (opens in a new tab)
Direct-reading Gastec detector tube 810-131L
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler 690-101
690-103
690-104
Other Passive GC-FID 575-001
Other Passive TD, GC 690-101
690-103
690-104
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
690-103
690-104
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.