Hazard search

Ethylene oxide

CAS number
75-21-8
Also known as
1,2-Epoxyethane · Ethylene oxide (by portable GC) · Ethylene oxide (Qazi-Ketcham) · Oxirane

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 1 ppm
8-hour TWA 1.8 mg/m³

Notations

  • Carc: carcinogen
  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 88 Passive GC-FID 575-005
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Chromosorb 106 tube (300mg) 226-358
NIOSH 1614
Ethylene oxide by GC-ECD
Method document (opens in a new tab)
Active (pump) Coated Anasorb 747 tube (100/50mg) GC-ECD 226-178
NIOSH 3702
Ethylene oxide by portable GC -PID
Method document (opens in a new tab)
Active (pump) Sample bag P GC-PID 231-01
OSHA 1010
Ethylene oxide by GC-ECD
Method document (opens in a new tab)
Active (pump) Coated Anasorb 747 tube (100/50mg) GC-ECD 226-178
ASTM D4413
Ethylene oxide by GC-FID
Method document (opens in a new tab)
Active (pump) CSC Charcoal tube (800/200mg) (or JXC Charcoal tube (630/315mg) - N/A from SKC) 226-16
ASTM D5578
Ethylene oxide by GC-ECD (HBr derivatisation)
Method document (opens in a new tab)
Active (pump) Treated Anasorb 747 tube (100/50mg) GC-ECD 226-178
Non-agency
Ethylene oxide by Colorimetric analysis
Direct-reading Gastec detector tube 810-163
810-163L
810-163LL
Non-agency
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Passive sampler 575-005
Non-agency 14 GC
Other Passive GC-ECD 575-005

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)