Hazard search

Carbon dioxide

CAS number
124-38-9
Also known as
Carbon dioxide (by portable GC) · Carbonic acid gas · CO2 · Dry ice

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 5000 ppm
8-hour TWA 9150 mg/m³
15-minute STEL 15000 ppm
15-minute STEL 27400 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
NIOSH 6603
Carbon dioxide by portable GC
Method document (opens in a new tab)
Active (pump) Five-layer Sampling Bags P GC-TCD 232-01
OSHA ID 172 Active (pump) GC-TCD 253-01
263-01
OSHA ID-172 GC
Non-agency
Carbon dioxide by Colorimetric analysis
Direct-reading Gastec Detector tube 810-2
Non-agency
Carbon dioxide by Colorimetric analysis
Passive Gastec Dosi-tube 810-2D
Other Passive DR 810-2D

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.