Hazard search
Fibres, refractory ceramic and special purpose
- CAS number
- No CAS number
- Also known as
- Refractory ceramic & special purpose fibres
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 5 mg/m³ |
Notations
- Carc: carcinogen
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| NIOSH 7400 Asbestos & other fibres by PCM Method document (opens in a new tab) | Active (pump) | BestChek filter cassettes | 225-320 | |
| Non-agency General fibres by PCM | Active (pump) | Cowled filter holder with gridded MCE filters | 225-54 225-1913 | |
| Other | Active (pump) | PCM | 225-1913 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)