SKC Vac-U-Chamber

The SKC Vac-U-Chamber is a rigid air sample box that allows sample bags to be filled directly by using negative pressure provided by most personal air sample pumps

Downloads

The SKC Vac-U-Chamber is a rigid air sample box that allows sample bags to be filled directly by using negative pressure provided by most personal air sample pumps. Because the sample does not pass through the pump, both pump and sample contamination are eliminated. All surfaces in contact with the sample are constructed of inert materials. The Vac-U-Chamber’s rigid walls will not collapse under vacuum conditions.

  • Allows direct filling of SKC air sample bags
    • Uses negative pressure provided by most personal air sample pumps
  • Protects sample pump from contamination
    • Sample does not pass through the pump
    • Sample contacts only inert tubing and bag
    • Sample line extends from contaminant source through case to bag
  • Rugged heavy-duty construction
    • Will not collapse under vacuum
    • Airtight
  • Four sizes available:
SizeSample Bag (L)Dimensions
Small1305 x 229 x 127 mm
Large8483 x 356 x 198 mm
Extra-Large10740 x 460 x 265 mm
Jumbo25784 x 660 x 394 mm

Applications:

  • Industrial VOCs
  • Indoor air quality
  • Effluent gas samples
  • Ground water testing
  • Stack sampling
  • Ventilation studies
  • Hazardous Material (HazMat) testing

Using the Vac-U-Chamber

The Vac-U-Chamber is equipped with three ¼ inch OD fitting ports for inflating sample bags:

  • Sample inlet port – for connecting to the sample line or gas source
  • Purge port – for purging the air prior to sampling or when preparing the bag for a standard
  • Vacuum port – for inflating a bag

An air sample bag is connected to the inside sample inlet port and the chamber is closed, providing an airtight seal. An air sample pump is connected to the outside vacuum outlet port. When activated, the pump evacuates air from inside the chamber. The sample bag inflates as a result of the interior pressure drop. This pneumatic technique allows the air sample to enter the bag directly without passing through the pump, protecting the pump from sample contaminants and the sample from pump contaminants.

Vac-U-Chambers Description

DescriptionPack Size Part Number
Small Vac-U-Chamber only with polypropylene fittings (supplied without pump), suitable for use with 1 L sample bags, 305x229x127 mmEach231-940
Large Vac-U-Chamber only with stainless steel fittings (supplied without pump), suitable for use with 8 L sample bags, 483x356x198 mmEach231-939
Extra-large Vac-U-Chamber only with polypropylene fittings (supplied without pump), suitable for use with 10 L sample bags, 740x460x265 mmEach231-944
Jumbo Vac-U-Chamber only with polypropylene fittings (supplied without pump), suitable for use with 25 L sample bags, 784x660x394 mmEach231-946

Kits

DescriptionPack Size Part Number
Large Vac-U-Chamber Kit, includes:

224-PCMTX8 Universal sample pump, 100-240V AC single charger, large Vac-U-Chamber and 10 x Tedlar 8 L Sample Bags (232-939)
Each224-4115MTX
Small Vac-U-Chamber Kit, includes:

224-PCMTX8 Universal Sample Pump, 100-240V AC single charger, small Vac-U-Chamber and 10 x Tedlar 1 L Sample Bags (232-01)
Each224-4124MTX

Accessories

DescriptionPack Size Part Number
FlexFoil PLUS 1 L Sample Bag with single polypropylene fitting, for use with small Vac-U-Chamber (231-940)10252-01
Tedlar 1 L Sample Bag with single polypropylene fitting, for use with small Vac-U-Chamber (231-940)10232-01
FlexFoil PLUS 8 L Sample Bag with single polypropylene fitting, for use with large Vac-U-Chamber (231-939)10252-08
Standard FlexFoil 8 L Sample Bag with single polypropylene fitting, for use with large Vac-U-Chamber (231-939)10262-08
Tedlar 8 L Sample Bag with single polypropylene fitting, for use with large Vac-U-Chamber (231-939)10232-939
FlexFoil PLUS 10 L Sample Bag with single polypropylene fitting, for use with Extra-large Vac-U-Chamber (231-944)10252-10
Tedlar 10 L Sample Bag with single polypropylene fitting, for use with Extra-large Vac-U-Chamber (231-944)10232-10
Tedlar 25 L Sample Bag with single polypropylene fitting, for use with Jumbo Vac-U-Chamber (231-946)10232-25
Replacement Quick Disconnect with tubing, for use with large Vac-U-Chamber (231-939)EachP231941
Replacement Quick Disconnect Polypropylene Female Connector, for use with small Vac-U-Chamber (231-940)EachP231942
Replacement Quick Disconnect Brass Female Connector, for use with large Vac-U-Chamber (231-939)EachP231943
PTFE Tubing, 5/16 inch OD (¼ inch ID)3 m231-937
PTFE Tubing, 5/16 inch OD (¼ inch ID15 m231-924