UMEX100 Passive Sampler CH2O

Meets OSHA Method 1007 specifications and conforms to EU ISO 16000-4-2004 with highly selective 2,4-DNPH chemistry for easy analysis

The UMEx 100 Passive Sampler for formaldehyde was developed in collaboration with the National Institute of Working Life in Umea, Sweden.

Constructed of tough polypropylene, the single-use UMEx 100 contains a tape treated with 2,4-dinitrophenylhydrazine (DNPH) for reliable collection of formaldehyde. Samplers are provided in individual aluminiumised pouches that can be used to transport the sampler to a laboratory after sampling.

For convenience and quality control assurance against contamination, each sampler incorporates a “blank/correction” section in addition to the active sampling section so there is no need to send extra samplers to the laboratory.

The shelf-life date is printed on a label on the outside of each pouch for easy inventory management. The UMEx 100 Sampler includes a clip for attachment to a worker’s collar for personal sampling or in an appropriate location for area sampling.

  • Accurate and reliable for formaldehyde collection
  • Accuracy exceeds OSHA standards
  • Uses popular 2,4-DNPH chemistry
  • Validated by OSHA and Swedish Institute
  • Economical low cost sampler
  • Easy to use – no pump or training required
  • Sample medium and blank/correction in one unit
  • Conforms to EU ISO 16000-4-2004
  • Documented uptake rates
    • For 15 minute to 24 hour samples
    • For 7 day samples*
  • Meets specifications of OSHA Method 1007†  
  • Referenced in EPA IP-6C
  • Highly sensitive and specific analysis method
  • Small and unobtrusive
  • Simple-to-use “on/off” sliding cover
  • Low 2 ppb limit of detection
  • Accurate and reliable for formaldehyde collection
  • Accuracy exceeds OSHA standards
  • Uses popular 2,4-DNPH chemistry
  • Validated by OSHA and Swedish Institute
  • Economical low cost sampler
  • Easy to use – no pump or training required
  • Sample medium and blank/correction in one unit
  • Conforms to EU ISO 16000-4-2004
  • Documented uptake rates
    • For 15 minute to 24 hour samples
    • For 7 day samples*
  • Meets specifications of OSHA Method 1007†  
  • Referenced in EPA IP-6C
  • Highly sensitive and specific analysis method
  • Small and unobtrusive
  • Simple-to-use “on/off” sliding cover
  • Low 2 ppb limit of detection
  • Safe – No glass or chemical liquids in the sampler
  • 28.6 ml/min uptake rate enhances sensitivity for 15 minute, 8 hour, and 24 hour sampling*  
  • Versatile sampler – suitable for both workplace sampling and long term indoor air sampling

Specifications

Sampling Rate28.6 ml/min with a RSD (Relative Standard Deviation) of 7.6% at wind velocity of 5 to 100 cm/sec for 15 minutes to 24 hours 20.4 ml/min at wind velocities < 5 cm/sec for 1 to 7 days
Detection Principle Formation of stable DNPH-hydrazone in the presence of formaldehyde
Validation Range 0.06 to 3.0 ppm
Lower Detection Limits 15 min: 200 ppb (0.24 mg/m3) 8 hrs: 5 ppb (0.006 mg/m3) 24 hrs: 2 ppb (0.002 mg/m3) 7 days: 0.2 ppb (0.0002 mg/m3)
Shelf-life12 months from date of manufacture at < 4°C (39.2°F)
Capacity 29 µg/sample
AnalysisSolvent extraction and analysis by HPLC (high-performance liquid chromatography) with UV detection
Accuracy ± 25%, exceeds OSHA requirements
StorageBefore use: < 4°C (39.2°F) After use: < 4°C (39.2°F) and analyze within 3 weeks. Do not store with food.
Temperature Effects No effect on sampling rate between 10 and 30°C
Wind Effects No effect from 5 to 100 cm/s
InterferencesLarge amounts of carbonyl compounds may reduce the uptake of formaldehyde Use in ozone levels <0.5 ppm
Dimensions8.6 x 2.8 x 0.89 cm
Weight10.8 g

Sampling Rates for Other Aldehydes

CompoundSampling Rate (mL/min)
Acetaldehyde22.8 ‡
Benzaldehyde13.5 ‡
Butyraldehyde15.8 ‡
Crotonaldehyde9.71 ‡
Glutaraldehyde14 ‡
Hexanaldehyde 9.66 ‡
Isovaleraldehyde15.5 ‡
Propionaldehyde 14 ‡
Chloroacetaldehyde19.4 **
Decylaldehyde 10.4 **
Heptanaldehyde12.8 **
Nonanaldehyde 11.6 **
o-Phthaldehyde12.83 **
o-Tolualdehyde12.7 **
Valeraldehyde15.4 **

‡  Partial Validation
** Calculated Sampling Rate

UMEx 100 Passive Samplers

DescriptionPack Size Part Number
UMEx 100 Passive Sampler for Formaldehyde  # and other Aldehydes.
Designed for single use only. DO NOT reuse UMEx samplers.
10500-100
UMEx 100 Passive Sampler for Formaldehyde  # and other Aldehydes.
Designed for single use only. DO NOT reuse UMEx samplers.
25500-100A
Treated Tape, for QC (quality control) purposes only50P20084

† If sampling in an atmosphere where Formalin is the source of Formaldehyde, please contact us.
# Limited shelf-life; storage required at <4°C. Do not store with food.

Accessories

DescriptionPart Number
Stand for Indoor Sampling690-302UMEX100 Passive Sampler CH2O
Shelter for Outdoor Sampling690-303 UMEX100 Passive Sampler CH2O