Specific Sorbent Tubes

Includes Carbon Beads, Drying Tubes, Firebrick, Florisil, Molecular Sieve, Oxidiser and Soda Lime tubes

A range of sorbent tubes utilising a variety of sorbent material.

To select a tube for a specific compound refer to the SKC Sampling Guides or use our SKC online Hazard Database

Carbon Beads Sorbent Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Carbon Beads
(potassium hydroxide)
/PTFE Filter
16 to
8 x 85
2100/50GOHWWWTT5226-142 *

Table Notes:

*  Limited shelf-life; contact us for more information.

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Protective Tube Covers:

H:  Specifically for use with 226-142 and 226-177 sorbent tubes

Drying Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Drying Tube10 x 1601900GSWW50226-44-02
Drying Tube6 x 701250GSWW50226-44

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Firebrick Sorbent Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Firebrick (Gas
chrom-R) (sulphuric acid)
7 x 701300GSBWW50226-42-02

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder – Do not use an adjustable low flow holder
V:  OVS Tube Holder – Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Florisil Sorbent Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Florisil6 x 702100/50GSAWWW50226-39
Florisil8 x 1102400/200GSBWWW50226-39-02

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder – Do not use an adjustable low flow holder
V:  OVS Tube Holder – Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Molecular Sieve Sorbent Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Molecular Sieve (triethanolamine)7 x 1102400/200GSBWWW50226-40-02
Molecular Sieve (triethanolamine) (1 tube)
Oxidizer
(1 tube)
Molecular Sieve (triethanolamine)
(1 tube)
(3 tubes total)
7 x 70

7 x 110

7 x 70
1

1

1
400

400

600
GS

GS

GS
WW

WW

WW
10
Sets
226-40A
Molecular sieve
(triethanolamine)
/oxidizer
/molecular sieve
(triethanolamine)
10 x 1103400/400/600GSCWWW10

50
226-182A

226-182

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder – Do not use an adjustable low flow holder
V:  OVS Tube Holder – Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Oxidiser Sorbent Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Oxidiser
Note: Currently unavailable
7 x 701800GSBWW20226-186

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder – Do not use an adjustable low flow holder
V:  OVS Tube Holder – Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Soda Lime Sorbent Tubes

Sorbent
(coating)
Size (mm)
ODxLength
SectionsSorbent
(mg)
EndsTube
Cover
SeparatorsPack
Size
Part Number
Soda Lime7 x 1102600/200GSBWWWW50226-210

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder – Do not use an adjustable low flow holder
V:  OVS Tube Holder – Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Traps for Volatile Organic Sampling Trains (VOSTs)

These are specified by the US EPA Method 0031 in SW-846 for sampling VOCs in gaseous effluent from stationary emission sources such as hazardous waste incinerators. SKC VOST traps meet method specifications, are tested for background and pressure drop, and feature Swagelok fittings and PTFE ferrules.

Note: Traps are not supplied thermally conditioned. They must be conditioned prior to use, and used and analysed within 14 days of conditioning.

ApplicationSorbent
(coating)
Size (mm)
ODxLength
EndsPack
Size
Part Number
EPA 0031 Tenax TA 35/60 mesh (1.6) 16 x 125GOEach226-134

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open