Coated (Treated) Filters

Coated (treated) Filters

  • Ready to use
  • Time-saving
  • Economical
  • No assembly required
  • Meet agency method specifications

SKC offers coated filters to meet a variety of OSHA, NIOSH, ASTM, and international agency methods. 

Some chemicals are not effectively trapped by any solid sorbent without special preparation. Chemical coating is carried out on various sorbents to trap aldehydes, nitrogen dioxide, amines and many more compounds. Coated filters make sampling reactive compounds fast and easy. They are a convenient alternative to wet chemistry methods using impingers. Simply unplug the lightweight cassette, insert it into an SKC Filter Cassette Holder, clip holder to a worker’s collar, and attach to a personal sampling pump. Use coated filters to collect compounds that exist as an aerosol or mist or for some higher boiling vapours. Flow rates are typically greater than 1 L/min and sampling times range from 15 minutes to one hour. Most coated filter samples are extracted in solvents and analysed by gas or liquid chromatography.

  • Ready to use
  • Time-saving
  • Convenient alternative to impinger wet chemistry methods
  • Economical
  • No assembly required – preloaded into cassettes with end plugs and shrink bands
  • Meet agency method specifications
  • No cumbersome collection liquids or glass
  • Easy personal sampling
  • Small package size for short shelf-life product

The methods listed are the most widely used. Note also that coated filters have a limited shelf life and are supplied in 37 mm cassettes unless otherwise noted.

ChemicalMethodFilter; CoatingPack Size Part Number
Acetic anhydrideOSHA 822 Glass fibre filters; 1-(2-pyridyl) piperazine10225-9009 §
Acetic anhydrideOSHA 1022 Glass fibre filters; veratrylamine and di-n-octyl phthalate10225-9010
4-AminobiphenylOSHA 932 Glass fibre filters; sulphuric acid10225-9004
AnilineNIOSH 20172 Glass fibre filters; sulphuric acid10225-9004 ¥
Arsenic, volatile compoundsOSHA ID-10061 MCE filter and plastic pad; untreated and 1 cellulose support pad; sodium carbonate10225-9001
BenzidineOSHA 652 Glass fibre filters; sulphuric acid10225-9004
Bromine, chlorineNIOSH 60111 25 mm PTFE pre-filter and polypropylene support; 1 25 mm specially cleaned silver membrane and polypropylene support in 25 mm cassette5225-9006
CrotonaldehydeOSHA 812 Glass fibre filters; 2,4-dinitrophenylhydrazine and phosphoric acid10225-9019 §
o-DianisidineOSHA 712 Glass fibre filters; sulphuric acid10225-9004
3,3-DichlorobenzidineOSHA 652 Glass fibre filters; sulphuric acid10225-9004
Diisocyanates &(HDI;2,6-TDI;2,4-TDI)ASTM D5836 Δ
OSHA 42
1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine10225-9013 §
Diisocyanates &(HDI;2,6-TDI;2,4-TDI)OSHA 421 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine10225-9002 §  
DiphenylamineOSHA 782 Glass fibre filters; sulphuric acid10225-9004
FluoridesOSHA ID-110
NIOSH 7902
ASTM D4765
1 MCE filter and cellulose pad; sodium carbonate10225-9001 #
Fluorides, particulateNIOSH 79062 Nitrocellulose filters; 1 coated with sodium carbonate, 1 uncoated10225-9031
GlutaraldehydeOSHA 642 Glass fibre filters; 2,4-dinitrophenyl hydrazine and phosphoric acid10225-9003 §
Hexavalent Chromium in Chromium Plating MistMDHS 52/425mm Polyvinylidine Fluoride Filter; sodium hydroxide (filters only)24225-9026
HydrazineOSHA 1082 Glass fibre filters; sulphuric acid10225-9012
Hydrofluoric acidNIOSH 79062 Nitrocellulose filters; 1 coated with sodium carbonate, 1 uncoated10225-9031
Hydrogen bromideNIOSH 79072 Quartz filters; sulphuric acid; 1 coated with sodium carbonate, 1 uncoated10225-9032
Hydrogen chlorideNIOSH 79072 Quartz filters; sulphuric acid; 1 coated with sodium carbonate, 1 uncoated10225-9032
Hydrogen PeroxideOSHA 10192 25 mm Quartz filters; titanium oxysulphate hydrate in 25 mm cassette10225-9030 (OSHA 1019)
Hydrogen PeroxideNON 572 25 mm Quartz filters; titanium oxysulphate hydrate in 25 mm cassette10225-9030 (NON 57)
IsocyanatesASTM 1 PTFE filter, 1 Glass filter treated with MAMA

(ISO-CHEK Sampling System)
12225-9022
IsocyanatesASTM 1 PTFE filter, 1 Glass filter treated with MAMA

(ISO-CHEK Sampling System)
36225-9022A
Isocyanates (HDI;2,6-TDI;2,4-TDI)ASTM D5836 Δ 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine10225-9013 §
Isocyanates (HDI;2,6-TDI;2,4-TDI)OSHA 42 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine36225-9002 §  
Isocyanates (HDI, MDI, TDI, IPDI, HDI-BT, HDI-IC)OR-OSHA 10101 Glass fibre filter; MAMA

13 mm preloaded in a 13 mm Swinnex holder
5225-9029 §
Isocyanates, organicMDHS 25/4 (UK)1 25 mm A/E Glass filter; methoxyphenyl piperazine (filters only)5Special Order §
n-IsopropylanilineOSHA 782 Glass fibre filters; sulphuric acid10225-9004
Maleic anhydrideOSHA 862 Glass fibre filters; veratrylamine10225-9021 §
Maleic anhydrideFor IFV1 25 mm Glass fibre filter; veratrylamine (filters only)10225-9028 §
Mercaptans
(methyl-, ethyl-, n-butyl, and phenyl-)
NIOSH 2542
OSHA 26
1 Glass fibre filter; mercuric acetate10225-9007 §
4,4′-Methylene bis (2-chloroaniline) (MOCA)OSHA 712 Glass fibre filters; sulphuric acid10225-9004
Methylene bisphenyl (MDI)OSHA 471 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine10225-9013 §
Methylene bisphenyl (MDI)OSHA 471 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine36225-9002 §  
4,4′-MethylenedianilineOSHA 57 Ω
NIOSH 5029
2 Glass fibre filters; sulphuric acid10225-9004
1-Naphthylamine, 2-naphthylamineOSHA 932 Glass fibre filters; sulphuric acid10225-9004
Nitric acidNIOSH 20172 Quartz filters; 1 coated with sodium carbonate, 1 uncoated10225-9032
NitrobenzeneNIOSH 20172 Glass fibre filters; sulphuric acid10225-9004 ¥
OzoneOSHA ID-2142 Glass fibre filters; nitrite-impregnated10225-9014 §
Peracetic AcidOSHA PV23211 Quartz filters (R-100); titanium oxysulphate hydrate (TiOSO4) preloaded in 25 mm 2-piece clear cassette10225-9037
Phenylenediamine (o-, m-, p-)OSHA 872 Glass fibre filters; sulphuric acid10225-9004
PhosphineOSHA 10031 Glass fibre filter; 1 polyester filter treated with mercuric chloride10225-9018 §
Phosphoric acidNIOSH 79081 Quartz filter10225-9033
Phthalic anhydrideOSHA 902 Glass Fibre filters, veratrylamine10225-9034 §
Sulphur dioxideNIOSH 6004 (modified)1 MCE pre-filter and support/1 cellulose filter and support; sodium carbonate10225-9005
Sulphuric acidNIOSH 79081 Quartz filter10225-9033
2,4-ToluendiamineOSHA 652 Glass fibre filters; sulphuric acid10225-9004
2,6-ToluendiamineOSHA 652 Glass fibre filters; sulphuric acid10225-9004
o-TolidineOSHA 712 Glass fibre filters; sulphuric acid10225-9004
o-ToluidineNIOSH 20172 Glass fibre filters; sulphuric acid10225-9004 ¥
Toluidine
(o-, m-, p-)
OSHA 732 Glass fibre filters; sulphuric acid10225-9004
1,3,5-Triglycidyl isocyanurate (TGI)OSHA PV20551 Glass fibre filter; hydrobromic acid10225-9027
ValeraldehydeOSHA 853 Glass fibre filters; 2,4-dinitrophenylhydrazine and phosphoric acid10225-9020 §
m-Xylenediamine (m-XDA, p-XDA)OSHA 1052 Glass fibre filters; sulphuric acid10225-9004
Filters

Notes

§ Storage below 4°C required

† Custom order due to very limited shelf-life

‡ While meeting the specifications of OSHA Methods 42 and 47, Coated Filter Part Number. 225-9002 contains a higher than specified loading of reagent to increase stability and shelf-life. Coated Filter Part Number 225-9002 traps both vapour and aerosol phases. SKC also offers Coated Filter Part Number 225-9013 that contains the specified reagent loading for OSHA 42 and 47, but has a freezer shelf-life of only three months.

∑ Meets multiple ASTM methods, see ISO-CHEK Cassettes

¥ NIOSH Method 2017 also requires SKC Sorbent Tube Part No. 226-15.

# Collects both vapour and aerosol phases of fluorides. The concept of sampling for fluorides in air using a double filter is patented in Canada by IRSST (Institut de recherche en santé et Robert-Suavé en sécurité du travail du Québec), Patent No. 1,299,114.

Ω OSHA 57 is an update of NIOSH 5029 which called for a single filter

¶ Requires Impinger, Part No. 225-36-1

• Also requires Sorbent Tube Part Number 226-193-UC or 226-199-UC for simultaneous, separate sampling of peracetic acid

Δ ASTM D5836 and D5932 for 2,4-TDI, 2,6-TDI only

♠ A coated filter is not needed for this method, as sulphuric acid and phosphoric acid are non-volatile acids and are present in the air as an aerosol.

♦ Requires impinger and sorbent trap for simultaneous sampling of PAA and Hydrogen Peroxide