BioStage

The BioStage® single-stage cascade impactor operates on the principle of inertial impaction and meets NIOSH and ACGIH recommendations for sampling indoor and outdoor air for viable microorganisms, including bacteria, and fungi

The BioStage single-stage cascade impactor operates on the principle of inertial impaction and meets NIOSH requirements and ACGIH recommendations for sampling indoor and outdoor air for viable microorganisms including bacteria and fungi. Made of precision-tooled aluminum, the sampler components are held together securely by the SureLock positive seal. Using a high flow pump such as the BioLite, air is drawn through the impactor where particles are impacted onto an agar collection medium.

  • Easy to use
  • Made of corrosion resistant aluminium and autoclavable
  • Collected organisms remain intact and viable
  • SureLock positive seal ensures sample integrity
  • Easy setup and calibration
  • Proven principle of operation
    • Meets ACGIH recommendations for bioaerosol sampling
    • Meets NIOSH Method 0800 and 0801 requirements
    • Performance equivalent to Andersen N-6 and Aerotech A6

Applications

  • Indoor Air Quality (IAQ) studies
  • Filter and cleanroom efficiency studies
  • Pharmaceutical production
  • Brewery fermentation
  • Animal care laboratories
  • Food processing areas
  • Sewage treatment plants
  • Hospital environments
  • Cosmetic manufacturing
  • Grain processing and transportation
  • Bio-risk response
Flow Rate28.3 L/min
MaterialInlet cone and base plate: Precision-tooled autoclavable aluminum O-rings: Duro 50, BUNA-N (not autoclavable )
Jet Classification Stage400 holes (0.25 mm hole diameter)
Median Cut-Point (D50)0.6 μm
Sample Media90 to 100 mm agar plates *
Suggested MediaFor bacteria: Tryptic Soy Agar (TSA) Blood Agar Plates (BAP) For fungi (viable): Potato Dextrose Agar (PDA) Malt Extract Agar (MEA) Dichloran Glycerol 18 Agar (DG-18) Corn Meal Agar (CMA)
AnalysisColony culture ‡
Tubing1/4 inch ID

* Requires microbiological media supplied by analytical laboratories
‡ In situations where spore counts are high, positive hole correction should be used

BioStage and Accessories

DescriptionPart Number
Standard BioStage single-stage cascade impactor225-9611BioStage
Calibration Adaptor for BioStage, attaches to the BioStage inletP33100BioStage
Tubing Adaptor for BioLite+ Pump to BioStage225-6202BioStage
Tripod Stand, 1.5m telescoping, for area sampling at breathing zone height228-506BioStage