title: "Uranium (7440-61-1): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/uranium-7440-61-1/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/uranium-7440-61-1/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/uranium-7440-61-1/
---

Hazard search

# Uranium

CAS number

7440-61-1

Also known as

U · Uranium (soluble compounds)

## UK workplace exposure limits

Our data hold no UK limit for this substance.

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 91/2** / Metals and Metalloids by XRF / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs91-2.pdf) | Active (pump) | IOM with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/#part-225-70a) / [225-1930](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-1930) |
| **OSHA ID 170SG** | Active (pump) |  | POL | [225-803](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/#part-225-803) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **OSHA ID-170SG** / Soluble Uranium by DPCSP / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-id170sg.pdf) | Active (pump) | 5µm PVC GLA5000 filter in cassette |  | [225-803](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/#part-225-803) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **BS ISO 15202-1:2020** / Determination of metals and metalloids in airborne particulate matter by ICP / [Method document (opens in a new tab)](https://shop.bsigroup.com/ProductDetail?pid=000000000030383009) | Active (pump) | IOM with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/#part-225-70a) / [225-1930](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-1930) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)