Hazard search

# Tetrasodium pyrophosphate

CAS number

7722-88-5

Also known as

Sodium diphosphate · Sodium pyrophosphate

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 5 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **OSHA ID 111** | Active (pump) |  | GR & IC | [225-5-37-P](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) / [225-2LF](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/#part-225-2lf) |
| **OSHA ID 121** | Active (pump) |  | AA or AES | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **OSHA ID-111** / Phosphoric acid by IC / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-id111.pdf) | Active (pump) | 0.8µm MCE filter with backup pad in 37mm cassette |  | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-5](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/#part-225-5) / [225-2LF](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/#part-225-2lf) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **OSHA ID-121** / Metal & metalloid particulates by AAS / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-id121.pdf) | Active (pump) | 0.8µm MCE filter with back-up pads |  | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-5](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/#part-225-5) / [225-2LF](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/#part-225-2lf) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)