# Silica, crystalline by IR

CAS number

No CAS number

## UK workplace exposure limits

Our data hold no UK limit for this substance.

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **NIOSH 7602** | Active (pump) |  | IR | [225-5-37-P](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) / [225-01-02](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-01-02) / [225-309](https://analyt-mtc.com/catalog/product/sureseal-cassette-blanks/#part-225-309) / [225-3851-PW](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/#part-225-3851-pw) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)