---
title: "Particulates not otherwise regulated, respirable fraction"
url: https://analyt-mtc.com/tools/hazard-search/particulates-not-otherwise-regulated-respirable-fraction/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/particulates-not-otherwise-regulated-respirable-fraction/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/particulates-not-otherwise-regulated-respirable-fraction/
---

Hazard search

# Particulates not otherwise regulated, respirable fraction

CAS number

No CAS number

## UK workplace exposure limits

Our data hold no UK limit for this substance.

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **OSHA PV2121** | Active (pump) |  | GR | [225-8208A](https://analyt-mtc.com/catalog/product/gla-5000-pvc-membrane-filters/#part-225-8208) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) / [225-105](https://analyt-mtc.com/catalog/product/gs-1-respirable-dust-cyclone/#part-225-105) / [225-3851-PW](https://analyt-mtc.com/catalog/product/disposable-parallel-particle-impactors/#part-225-3851-pw) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)
