title: "Methyl tert-butyl ether (1634-04-4): sampling methods"
url: https://analyt-mtc.com/tools/hazard-search/methyl-tert-butyl-ether-1634-04-4/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/methyl-tert-butyl-ether-1634-04-4/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/methyl-tert-butyl-ether-1634-04-4/
---

Hazard search

# Methyl tert-butyl ether

CAS number

1634-04-4

Also known as

Methyl t-butyl ether · Methyl-t-butyl-ether (MTBE) · Methyl-tert-butyl ether (see online Passive Sampling Guide) · MTBE · t-Butyl methyl ether (methyl t-butyl ether, MTBE) · t-Butyl methyl ether (MTBE) · tert-Butyl methyl ether

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 50 ppm |  |
| 8-hour TWA | 183.5 mg/m³ |  |
| 15-minute STEL | 100 ppm |  |
| 15-minute STEL | 367 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 88** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs88.pdf) | Passive | Passive sampler | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) |
| **MDHS 96** | Active (pump) |  | GC-FID | [226-09](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **MDHS 96** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf) | Active (pump) | Set of two Charcoal Tubes (400mg, 200mg) |  | [226-37](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-37) |
| **NIOSH 1615** / Methyl tert-butyl ether by GC-FID / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1615.pdf) | Active (pump) | Set of two charcoal tubes (400mg, 200mg) | GC-FID | [226-37](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-37) |
| **EPA TO-17** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](https://www.epa.gov/sites/default/files/2019-11/documents/to-17r.pdf) | Active (pump) | Two Thermal Desorption tubes | TD, GC | [226-350](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-350) / [226-347](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-347) / [224-26-02](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/#part-224-26-02) / [224-26-CPC](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/#part-224-26-cpc) |
| **Non-agency** / VOCs by solvent extraction and GC / [Method document (opens in a new tab)](https://www.skcltd.com/images/pdfs/ULTRA_Selection_Guide_April_2017.pdf) | Passive | Anasorb CSC (500mg) passive sampler |  | [690-105](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-105) |
| **Other** | Passive |  | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) |
| **Other** | Passive |  | GC-FID | [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **Other** | Passive |  | GC-FID | [690-105](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-105) |
| **Other Internal** | Passive |  | GC-FID | [690-105](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-105) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)