title: "Methidathion (950-37-8): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/methidathion-950-37-8/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/methidathion-950-37-8/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/methidathion-950-37-8/
---

Hazard search

# Methidathion

CAS number

950-37-8

Also known as

O,O-Dimethyl-S-(5-methoxy-1,3,4-thiadiazolinyl-3-methyl) dithiophosphate

## UK workplace exposure limits

Our data hold no UK limit for this substance.

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **OSHA PV2074** | Active (pump) |  | GC-ECD | [226-30-16](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/#part-226-30-16) |
| **OSHA PV2074** / Methidathion by GC-ECD / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-pv2074.pdf) | Active (pump) | OVS-2 tube |  | [226-58](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/#part-226-58) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)