title: "Lead oxide (1317-36-8): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/lead-oxide-1317-36-8/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/lead-oxide-1317-36-8/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/lead-oxide-1317-36-8/
---

Hazard search

# Lead oxide

CAS number

1317-36-8

Also known as

Lead (II) oxide (by field portable XRF) · Lead (II) oxide (by portable ultrasound extraction/ASV) · Lead monoxide · Lead oxide (as lead) · Lead oxide (as Pb) · Lead(II) oxide · Plumbous oxide

## UK workplace exposure limits

Our data hold no UK limit for this substance.

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **NIOSH 7082** / Lead & compounds by AAS-F / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7082.pdf) | Active (pump) | 0.8µm MCE filter in 37mm cassette | AAS-F | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **NIOSH 7105** / Lead & compounds by AAS -GF / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7105.pdf) | Active (pump) | 0.8µm MCE filter in 37mm cassette | AAS-GF | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **NIOSH 7701** / Lead by Portable Ultrasonic Extraction/ASV / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7701.pdf) | Active (pump) | 0.8µm MCE filter in 37mm cassette | P ASV | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **NIOSH 7702** / Lead by field portable XRF / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7702.pdf) | Active (pump) | 0.8µm MCE filter with back-up pad in 37mm cassette | XRF | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)