title: "Fluoride (16984-48-8): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/fluoride-16984-48-8/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/fluoride-16984-48-8/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/fluoride-16984-48-8/
---

Hazard search

# Fluoride

CAS number

16984-48-8

Also known as

F- · Fluoride (inorganic as F) · Fluoride (particulate) · Fluoride ion · Fluorides · Fluorides (aerosol & gas by ISE) · Fluorides (as F)

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 2.5 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **NIOSH 7902** / Fluorides by ISE / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7902.pdf) | Active (pump) | Coated MCE filter in cassette | ISE | [225-9001](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9001) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **NIOSH 7906** / Fluorides by IC / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7906.pdf) | Active (pump) | Coated MCE filter in cassette | IC-CD | [225-9031](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9031) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **OSHA ID 110** | Active (pump) |  | ISE | [225-9001](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9001) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **OSHA ID-110** / Fluoride (F & HF) by ISE / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-id110.pdf) | Active (pump) | Coated MCE filter in cassette |  | [225-9001](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9001) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **ASTM D4765** / Fluorides by ISE / [Method document (opens in a new tab)](http://www.astm.org/Standards/D4765.htm) | Active (pump) | Coated MCE filter in cassette | ISE | [225-9001](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9001) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **Other Contact SKC** | Active (pump) |  | IC | [225-70A](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/#part-225-70a) / [225-1930](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-1930) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)