# Ethylamine

CAS number

75-04-7

Also known as

Aminoethane · Ethanamine

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 2 ppm |  |
| 8-hour TWA | 3.8 mg/m³ |  |
| 15-minute STEL | 6 ppm |  |
| 15-minute STEL | 11 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **OSHA 36** / Ethylamine by HPLC/UV / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-36.pdf) | Active (pump) | Coated XAD-7 tube (100/50mg) | HPLC-UV | [226-96](https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/#part-226-96) |
| **Non-agency** / Ethylamine by Colorimetric analysis | Direct-reading | Gastec detector tube |  | [810-180](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-180) / [810-180L](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-180l) |
| **Other** | Passive |  | HPLC-UV |  |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.