title: "Epichlorohydrin (106-89-8): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/epichlorohydrin-106-89-8/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/epichlorohydrin-106-89-8/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/epichlorohydrin-106-89-8/
---

Hazard search

# Epichlorohydrin

CAS number

106-89-8

Also known as

1-Chloro-2,3-epoxypropane · 1-Chloro-2,3-epoxypropane (epichlorohydrin)

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 0.5 ppm |  |
| 8-hour TWA | 1.9 mg/m³ |  |
| 15-minute STEL | 1.5 ppm |  |
| 15-minute STEL | 5.8 mg/m³ |  |

### Notations

-   Carc: carcinogen

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 72** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs72.pdf) | Active (pump) | Chromosorb 106 thermal desorption tube (300mg) | TD, GC | [226-358](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/#part-226-358) |
| **MDHS 80** | Active (pump) |  | TD, GC | [226-358](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/#part-226-358) |
| **MDHS 88** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs88.pdf) | Passive | Passive sampler | GC-FID | [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **MDHS 96** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **MDHS 104** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs104.pdf) | Active (pump) | Tenax TA Tube (250 mg) or Chromosorb 106 Tube (300 mg) |  | [226-357](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/#part-226-357) / [226-358](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/#part-226-358) |
| **NIOSH 1010** / Epichlorohydrin by GC-FID / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1010.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **Non-agency** / Epichlorohydrin by Colorimetric analysis | Direct-reading | Gastec detector tube |  | [810-163L](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-163l) |
| **Other** | Passive |  | GC-FID | [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)