title: "Diisopropylamine (108-18-9): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/diisopropylamine-108-18-9/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/diisopropylamine-108-18-9/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/diisopropylamine-108-18-9/
---

Hazard search

# Diisopropylamine

CAS number

108-18-9

Also known as

DIPA · N-Isopropyl-2-propanamine

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 5 ppm |  |
| 8-hour TWA | 21 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **OSHA CSI** | Active (pump) |  | GC-ECD | [225-36-2](https://analyt-mtc.com/catalog/product/skc-impingers/#part-225-36-2) / [225-36-1](https://analyt-mtc.com/catalog/product/skc-impingers/#part-225-36-1) / [225-22](https://analyt-mtc.com/catalog/product/biosampler/#part-225-22) |
| **Non-agency** / Diisopropylamine by Colorimetric analysis | Direct-reading | Gastec detector tube |  | [810-180](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-180) / [810-180L](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-180l) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)