title: "Dicyclopentadiene (77-73-6): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/dicyclopentadiene-77-73-6/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/dicyclopentadiene-77-73-6/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/dicyclopentadiene-77-73-6/
---

Hazard search

# Dicyclopentadiene

CAS number

77-73-6

Also known as

Bicyclopentadiene · Cyclopentadiene dimer · Dicylopentadiene

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 5 ppm |  |
| 8-hour TWA | 27 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 88** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs88.pdf) | Passive | Passive sampler | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **OSHA PV2098** / Dicyclopentadiene by GC-FID / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-pv2098.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **Other** | Passive |  | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)