title: "Cumene (98-82-8): exposure limits and sampling — Analyt-MTC"
url: https://analyt-mtc.com/tools/hazard-search/cumene-98-82-8/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/cumene-98-82-8/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/cumene-98-82-8/
---

Hazard search

# Cumene

CAS number

98-82-8

Also known as

2-Phenylpropane · Cumene (isopropyl benzene) · Cumene (isopropyl benzene) (Hydrocarbons, Aromatic) · Isopropyl benzen (cumene) · Isopropyl Benzene (cumene) · Isopropyl benzene (cumene) (see online Passive Sampling Guide) · Isopropylbenzene

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 25 ppm |  |
| 8-hour TWA | 125 mg/m³ |  |
| 15-minute STEL | 50 ppm |  |
| 15-minute STEL | 250 mg/m³ |  |

### Notations

-   Sk: can be absorbed through the skin

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 72** | Active (pump) |  | TD, GC | [226-358](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/#part-226-358) |
| **MDHS 72** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs72.pdf) | Active (pump) | Tenax thermal desorption tube (250mg) |  | [226-357](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/#part-226-357) |
| **MDHS 80** | Active (pump) |  | TD, GC | [226-358](https://analyt-mtc.com/catalog/product/skc-chromosorb-sorbent-tubes/#part-226-358) |
| **MDHS 88** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs88.pdf) | Passive | Passive sampler | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **MDHS 96** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **MDHS 104** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs104.pdf) | Active (pump) | Tenax TA Tube (250 mg) |  | [226-357](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/#part-226-357) |
| **NIOSH 1501** / Hydrocarbons (aromatic) by GC-FID / [Method document (opens in a new tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1501.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **OSHA PV2137** / Cumene by GC-FID / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-pv2137.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **EPA TO-17** | Active (pump) |  | TD, GC | [226-350](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-350) / [226-347](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-347) / [224-26-02](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/#part-224-26-02) / [224-26-CPC](https://analyt-mtc.com/catalog/product/skc-gas-and-vapour-sampling-accessories/#part-224-26-cpc) |
| **EPA TO-17** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](https://www.epa.gov/sites/default/files/2019-11/documents/to-17r.pdf) | Active (pump) | Two Thermal Desorption tubes |  |  |
| **EPA TO-17** / Toxic Organic Compounds by thermal desorption and GC / [Method document (opens in a new tab)](http://www.epa.gov/ttn/amtic/files/ambient/airtox/to-17r.pdf) | Passive | Passive sampler |  |  |
| **Non-agency** / Cumene by Colorimetric analysis | Direct-reading | Gastec detector tube |  | [810-122L](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-122l) |
| **Non-agency** / VOCs by solvent extraction and GC / [Method document (opens in a new tab)](https://www.skcltd.com/images/pdfs/ULTRA_Selection_Guide_April_2017.pdf) | Passive | Anasorb CSC (500mg) passive sampler |  | [690-105](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-105) |
| **Non-agency** / VOCs by thermal desorption and GC / [Method document (opens in a new tab)](https://www.skcltd.com/images/pdfs/ULTRA_Selection_Guide_April_2017.pdf) | Passive | Anasorb GBC1 (370mg) or Tenax TA (265 mg) passive sampler |  | [690-101](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-101) / [690-104](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-104) |
| **Non-agency** / Cumene by Colorimetric analysis | Passive | Gastec Dosi-tube |  | [810-122DL](https://analyt-mtc.com/catalog/product/gastec-passive-dosi-tubes/#part-gst-122dl) |
| **Other** | Passive |  | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **Other** | Passive |  | TD, GC | [690-101](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-101) / [690-104](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-104) |
| **Other** | Passive |  | GC-FID | [690-105](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-105) |
| **Other** | Passive |  | DR | [810-122DL](https://analyt-mtc.com/catalog/product/gastec-passive-dosi-tubes/#part-gst-122dl) |
| **Other Internal** | Passive |  | TD, GC | [690-101](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-101) / [690-104](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-104) |
| **Other Internal** | Passive |  | GC-FID | [690-105](https://analyt-mtc.com/catalog/product/skc-ultra-passive-samplers/#part-690-105) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)