title: "Butyl carbitol (112-34-5): exposure limits and sampling"
url: https://analyt-mtc.com/tools/hazard-search/butyl-carbitol-112-34-5/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/butyl-carbitol-112-34-5/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/butyl-carbitol-112-34-5/
---

Hazard search

# Butyl carbitol

CAS number

112-34-5

Also known as

2-(2-Butoxyethoxy)ethanol · Butyl carbitol (diethylene glycol monobutyl ether) · Butyl diglycol · Butyl diglycol (Diethylene glycol butyl ether) · Diethylene glycol butyl ether · Diethylene glycol monobutyl ether · Diethylene glycol monobutyl ether (Butyl Diglycol)

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 10 ppm |  |
| 8-hour TWA | 67.5 mg/m³ |  |
| 15-minute STEL | 15 ppm |  |
| 15-minute STEL | 101.2 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 104** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs104.pdf) | Active (pump) | Charcoal tube (100/50mg) |  | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **OSHA PV2095** / Butyl Carbitol by gas chromatography with a flame ionization detector GC-FID / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-pv2095.pdf) | Active (pump) | Sorbent Tube | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **Non-agency** / VOCs by solvent desorption and GC-FID / [Method document (opens in a new tab)](https://www.skcltd.com/images/pdfs/VOC_Chek_575_Series-Selection_Guide.pdf) | Passive | Passive sampler |  | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **Other** | Passive |  | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)