CAS number

No CAS number

Also known as

As, sodium arsenite and arsenic trichloride, arsenic pentoxide and arsenates (e.g. lead arsenate and calcium arsenate)

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 0.1 mg/m³ |  |

### Notations

-   Carc: carcinogen

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 91/2** / Metals & metalloids by XRF / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs91-2.pdf) | Active (pump) | IOM with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/#part-225-70a) / [225-1930](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-1930) |
| **NIOSH 502** / organo-Arsenic by IC / [Method document (opens in a new tab)](https://www.cdc.gov/niosh/docs/2003-154/pdfs/5022.pdf) | Active (pump) | 1µm PTFE filter in cassette |  | [225-17-01](https://analyt-mtc.com/catalog/product/ptfe-polytetrafluoroethylene-filters/#part-225-17-01) / [225-3LF](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-3lf) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |
| **NIOSH 7900** / Arsenic & compounds (except AsH3 & As2O3) by AAS / [Method document (opens in a new tab)](https://www.cdc.gov/niosh/docs/2003-154/pdfs/7900.pdf) | Active (pump) | 0.8µm MCE filter in cassette (or Solu-CAP cassette) |  | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-8517](https://analyt-mtc.com/catalog/product/cassette-inserts/#part-225-8517) |
| **OSHA 1006** / Arsenic, Cadmium, Cobalt, Copper, Lead & Nickel by ICP -MS / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-1006.pdf) | Active (pump) | 0.8µm MCE filter with coated back-up pad in cassette |  | [225-9001](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9001) |
| **BS ISO 15202-1: 2020** / Determination of metals and metalloids in airborne particulate matter by ICP | Active (pump) | IOM with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/#part-225-70a) / [225-1930](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-1930) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html)