# Aluminium alkyl compounds

CAS number

No CAS number

Also known as

See individual compounds

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 2 mg/m³ |  |

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **OSHA ID-121** / Metal & metalloid particulates by AAS / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-id121.pdf) | Active (pump) | 0.8µm MCE filter in cassette | AAS | [225-3-01](https://analyt-mtc.com/catalog/product/mixed-cellulose-ester-membrane-filters/#part-225-3-01) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.