CAS number

107-98-2

Also known as

1-Methoxy-2-hydroxypropane · 1-Methoxy-2-propanol (glycol ethers) · 1-Methoxy-2-propanol (propylene glycol monomethyl ether) · 1-Methoxy-2-propanol (see online Passive Sampling Guide) · 1-Methoxypropan-2-ol · Isoamyl acetate (see online Passive Sampling Guide) · Propylene glycol methyl ether · Propylene glycol monomethyl ether · Propylene glycol monomethyl ether (1-methoxy-2-propanol) · Propylene glycol monomethyl ether (glycol ethers) · Propylene glycol monomethyl ether (see online Passive Sampling Guide)

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 100 ppm |  |
| 8-hour TWA | 375 mg/m³ |  |
| 15-minute STEL | 150 ppm |  |
| 15-minute STEL | 560 mg/m³ |  |

### Notations

-   Sk: can be absorbed through the skin

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 72** | Active (pump) |  | TD, GC | [226-357](https://analyt-mtc.com/catalog/product/skc-tenax-sorbent-tubes/#part-226-357) |
| **MDHS 88** / VOCs by solvent desorption and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs88.pdf) | Passive | Passive sampler | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) / [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |
| **MDHS 104** / VOCs by solvent and GC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs104.pdf) | Active (pump) | Anasorb 747 tube(140/70mg) |  | [226-81A](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-81a) |
| **NIOSH 2554** / Glycol ethers by GC-FID / [Method document (opens in a new tab)](https://www.cdc.gov/niosh/docs/2003-154/pdfs/2554.pdf) | Active (pump) | Anasorb 747 tube (140/70mg) | GC-FID | [226-81A](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/#part-226-81a) |
| **OSHA 99** / Propylene glycol monomethyl ethers/acetates by GC-FID / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-99.pdf) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | [226-01](https://analyt-mtc.com/catalog/product/skc-anasorb-sorbent-tubes/) |
| **Non-agency** / 1-Methoxy-2-propanol by Colorimetric analysis | Direct-reading | Gastec detector tube |  | [810-113L](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-113l) / [810-113LL](https://analyt-mtc.com/catalog/product/gastec-colour-gas-detector-tubes/#part-gst-113ll) |
| **Other** | Passive |  | GC-FID | [575-001](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-001) |
| **Other** | Passive |  | GC-FID | [575-002](https://analyt-mtc.com/catalog/product/skc-organic-vapour-passive-samplers/#part-575-002) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.