---
title: "1,6-Hexamethylene diisocyanate homopolymer (28182-81-2)"
url: https://analyt-mtc.com/tools/hazard-search/1-6-hexamethylene-diisocyanate-homopolymer-28182-81-2/
lang: en
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/1-6-hexamethylene-diisocyanate-homopolymer-28182-81-2/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/1-6-hexamethylene-diisocyanate-homopolymer-28182-81-2/
---

Hazard search

# 1,6-Hexamethylene diisocyanate homopolymer

CAS number

28182-81-2

Also known as

Hexamethylene diisocyanate, oligomers · Poly(hexamethylene diisocyanate) · Polymeric HDI

## UK workplace exposure limits

| Limit | Value | Applies to |
| --- | --- | --- |
| 8-hour TWA | 0.02 mg/m³ |  |
| 15-minute STEL | 0.07 mg/m³ |  |

### Notations

-   Sen: can cause sensitisation

## Sampling methods

| Method | Sampling | Medium | Analysis | Part numbers |
| --- | --- | --- | --- | --- |
| **MDHS 25/4** / Organic Isocyanates in air (aerosols) by HPLC -EC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs25-4.pdf) | Active (pump) | Midget impinger & coated glass fibre filter |  | [225-36-4](https://analyt-mtc.com/catalog/product/skc-impingers/#part-225-36-4) / [225-22](https://analyt-mtc.com/catalog/product/biosampler/#part-225-22) / [225-1109](https://analyt-mtc.com/catalog/product/cassette-and-filter-holders/#part-225-1109) |
| **MDHS 25/4** / Organic Isocyanates in air (vapours only) by HPLC -EC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs25-4.pdf) | Active (pump) | Stainless Steel IOM with coated glass fibre filter |  | [225-79A](https://analyt-mtc.com/catalog/product/iom-sampler/#part-225-79a) |
| **MDHS 25/4** / Organic Isocyanates in air (aerosols per Appendix 2) by HPLC -EC / [Method document (opens in a new tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs25-4.pdf) | Active (pump) | Stainless Steel IOM with coated glass fibre filter |  | [225-79A](https://analyt-mtc.com/catalog/product/iom-sampler/#part-225-79a) |
| **OSHA 5002** / Organic Vapour Sampling Group 3-diisocyanates- by UHPLC-FD / [Method document (opens in a new tab)](https://www.osha.gov/sites/default/files/methods/osha-5002.pdf) | Active (pump) | Glass fibre filter & support pad in open-face cassette | HPLC-UV or HPLC-FD | [225-9002](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9002) / [225-9013](https://analyt-mtc.com/catalog/product/skc-coated-treated-filters/#part-225-9013) / [225-1](https://analyt-mtc.com/catalog/product/aluminium-respirable-dust-cyclone/#part-225-1) |

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: [SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)](https://international.skcinc.com/sampling-guides/)
