title: "Calciumhydroxid, einatembare Fraktion (1305-62-0)"
url: https://analyt-mtc.com/de/tools/gefahrstoffsuche/calcium-hydroxide-inhalable-fraction-1305-62-0/
lang: de
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/calcium-hydroxide-inhalable-fraction-1305-62-0/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/calcium-hydroxide-inhalable-fraction-1305-62-0/
---

Gefahrstoffsuche

# Calciumhydroxid, einatembare Fraktion

CAS-Nummer

1305-62-0

Englischer Name

Calcium hydroxide - inhalable fraction

Auch bekannt als

Calciumhydroxid · Löschkalk · Kalkhydrat · Calcium dihydroxide · Calcium hydrate · Calcium hydroxide · Calcium hydroxide (calcium) · Calcium hydroxide (see Particulates Not Otherwise Regulated, total and respirable) · Calcium hydroxide - respirable fraction · Hydrated lime · Slaked lime

## Arbeitsplatzgrenzwerte (UK)

| Grenzwert | Wert | Gilt für |
| --- | --- | --- |
| 8-Stunden-Mittelwert (TWA) | 5 mg/m³ | Calcium hydroxide - inhalable fraction |
| 8-Stunden-Mittelwert (TWA) | 1 mg/m³ | Calcium hydroxide - respirable fraction |
| 15-Minuten-Kurzzeitwert (STEL) | 4 mg/m³ | Calcium hydroxide - respirable fraction |

## Probenahmeverfahren

| Verfahren | Probenahme | Sammelmedium | Analyse | Bestellnummern |
| --- | --- | --- | --- | --- |
| **MDHS 14/4** / General inhalable or respirable dusts by gravimetric analysis (total inhalable) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf) | Aktiv (Pumpe) | IOM sampler |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) |
| **MDHS 14/4** / General inhalable or respirable dusts by gravimetric analysis (respirable) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf) | Aktiv (Pumpe) | IOM sampler & foam, or cyclone |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-772](https://analyt-mtc.com/de/catalog/product/iom-sampler-2/#part-225-772) / [225-69](https://analyt-mtc.com/de/catalog/product/plastic-cyclone-2/#part-225-69) |
| **NIOSH 7020** / Calcium and compounds, as Ca by AA-F / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.cdc.gov/NIOSH/DOCS/2003-154/pdfs/7020.pdf) | Aktiv (Pumpe) | Filter Cassette | AA-F | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-3100](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3100) |
| **OSHA ID 121** | Aktiv (Pumpe) |  | AA or AES | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **OSHA ID-121** / Metal & metalloid particulates in Workplace Atmospheres by AA/AES / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.osha.gov/sites/default/files/methods/osha-id121.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **BS ISO 15202-1: 2020** / Determination of metals and metalloids in airborne particulate matter by ICP | Aktiv (Pumpe) | IOM with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-1930](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-1930) |
| **BS ISO 15202-1: 2020** / Determination of metals and metalloids in airborne particulate matter by ICP | Aktiv (Pumpe) | IOM with 0.8µm MCE filter and foam |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-1930](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-1930) / [225-772](https://analyt-mtc.com/de/catalog/product/iom-sampler-2/#part-225-772) |
| **Other** |  |  |  |  |

Verfahren und Grenzwerte wie von den Stellen veröffentlicht und von SKC zusammengefasst; prüfen Sie vor der Probenahme das aktuelle Verfahren und den für Sie geltenden Grenzwert. Die Grenzwerte sind die britischen (EH40), nicht die deutschen (TRGS 900).

Quelle: [SKC Ltd (UK), Hazard Search, used with SKC's permission (öffnet in einem neuen Tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (öffnet in einem neuen Tab)](https://international.skcinc.com/sampling-guides/)