title: "Aluminiumoxide (einatembar) (1344-28-1): Probenahme"
url: https://analyt-mtc.com/de/tools/gefahrstoffsuche/aluminium-oxides-inhalable-1344-28-1/
lang: de
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/aluminium-oxides-inhalable-1344-28-1/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/aluminium-oxides-inhalable-1344-28-1/
---

Gefahrstoffsuche

# Aluminiumoxide (einatembar)

CAS-Nummer

1344-28-1

Englischer Name

Aluminium oxides (inhalable)

Auch bekannt als

Aluminiumoxid · Tonerde · Korund · alpha-Alumina · alpha-Alumina (respirable fraction) · alpha-Alumina (total dust) · Alumina · Alumina (aluminum & compounds \[total dust as Al\]) · Alumina (particulates, respirable) · Alumina (particulates, total) · Aluminium oxides (respirable)

## Arbeitsplatzgrenzwerte (UK)

| Grenzwert | Wert | Gilt für |
| --- | --- | --- |
| 8-Stunden-Mittelwert (TWA) | 10 mg/m³ | Aluminium oxides (inhalable) |
| 8-Stunden-Mittelwert (TWA) | 4 mg/m³ | Aluminium oxides (respirable) |

## Probenahmeverfahren

| Verfahren | Probenahme | Sammelmedium | Analyse | Bestellnummern |
| --- | --- | --- | --- | --- |
| **MDHS 14/4** / General inhalable or respirable dusts by gravimetric analysis (respirable) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf) | Aktiv (Pumpe) | IOM & foam (or cyclone) with GF filter |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-58F](https://analyt-mtc.com/de/catalog/product/glass-fibre-depth-filters-2/#part-225-58f) / [225-772](https://analyt-mtc.com/de/catalog/product/iom-sampler-2/#part-225-772) / [225-69](https://analyt-mtc.com/de/catalog/product/plastic-cyclone-2/#part-225-69) |
| **MDHS 14/4** / General inhalable or respirable dusts by gravimetric analysis (total inhalable) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf) | Aktiv (Pumpe) | IOM with GF filter |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-58F](https://analyt-mtc.com/de/catalog/product/glass-fibre-depth-filters-2/#part-225-58f) |
| **NIOSH 0500** | Aktiv (Pumpe) |  | GR | [225-5-37-P](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-2LF](https://analyt-mtc.com/de/catalog/product/sureseal-cassette-blanks-2/#part-225-2lf) |
| **NIOSH 0600** | Aktiv (Pumpe) |  | GR | [225-01-02](https://analyt-mtc.com/de/catalog/product/aluminium-respirable-dust-cyclone-2/#part-225-01-02) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-8208A](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-8208) / [225-3851-PW](https://analyt-mtc.com/de/catalog/product/disposable-parallel-particle-impactors-2/#part-225-3851-pw) |
| **NIOSH 7013** / Aluminium & compounds by AAS / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7013.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette | AA-F | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **OSHA ID-121** / Metal & metalloid particulates by AAS / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.osha.gov/sites/default/files/methods/osha-id121.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **OSHA ID-198SG** / Aluminium oxide by AAS / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.osha.gov/sites/default/files/methods/osha-id198sg.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) |
| **OSHA PV2121** / Gravimetric Determination / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.osha.gov/sites/default/files/methods/osha-pv2121.pdf) | Aktiv (Pumpe) | Preloaded Filter Cassette | GR | [225-803](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-803) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-105](https://analyt-mtc.com/de/catalog/product/gs-1-respirable-dust-cyclone-2/#part-225-105) / [225-8208A](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-8208) / [225-3851-PW](https://analyt-mtc.com/de/catalog/product/disposable-parallel-particle-impactors-2/#part-225-3851-pw) / [225-8204A](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-8204a) / [225-2LF](https://analyt-mtc.com/de/catalog/product/sureseal-cassette-blanks-2/#part-225-2lf) |

Verfahren und Grenzwerte wie von den Stellen veröffentlicht und von SKC zusammengefasst; prüfen Sie vor der Probenahme das aktuelle Verfahren und den für Sie geltenden Grenzwert. Die Grenzwerte sind die britischen (EH40), nicht die deutschen (TRGS 900).

Quelle: [SKC Ltd (UK), Hazard Search, used with SKC's permission (öffnet in einem neuen Tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (öffnet in einem neuen Tab)](https://international.skcinc.com/sampling-guides/)