title: "Aluminium (einatembarer Staub) (7429-90-5): Probenahme"
url: https://analyt-mtc.com/de/tools/gefahrstoffsuche/aluminium-inhalable-dust-7429-90-5/
lang: de
alternates:
  en: https://analyt-mtc.com/tools/hazard-search/aluminium-inhalable-dust-7429-90-5/
  de: https://analyt-mtc.com/de/tools/gefahrstoffsuche/aluminium-inhalable-dust-7429-90-5/
---

Gefahrstoffsuche

# Aluminium (einatembarer Staub)

CAS-Nummer

7429-90-5

Englischer Name

Aluminium (inhalable dust)

Auch bekannt als

Aluminium · Al · Aluminium (respirable dust) · Aluminium metal (inhalable dust) · Aluminium metal (respirable dust) · Aluminium powder · Aluminum & compounds (total dust as Al) · Aluminum (Elements by Cellulosic Internal Capsule Sampler) · Aluminum (Elements by ICP Aqua Regia Ashing) · Aluminum (Elements by ICP HNO3 Digestion) · Aluminum (Elements by ICP HNO3/HClO4 Ashing) · Aluminum (respirable fraction) · Aluminum (total dust) · Aluminum soluble salts

## Arbeitsplatzgrenzwerte (UK)

| Grenzwert | Wert | Gilt für |
| --- | --- | --- |
| 8-Stunden-Mittelwert (TWA) | 10 mg/m³ | Aluminium (inhalable dust) |
| 8-Stunden-Mittelwert (TWA) | 4 mg/m³ | Aluminium (respirable dust) |

## Probenahmeverfahren

| Verfahren | Probenahme | Sammelmedium | Analyse | Bestellnummern |
| --- | --- | --- | --- | --- |
| **MDHS 14/4** / General inhalable or respirable dusts by gravimetric analysis (respirable) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf) | Aktiv (Pumpe) | IOM & foam (or cyclone) with GF filter | GR | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-58F](https://analyt-mtc.com/de/catalog/product/glass-fibre-depth-filters-2/#part-225-58f) / [225-772](https://analyt-mtc.com/de/catalog/product/iom-sampler-2/#part-225-772) / [225-69](https://analyt-mtc.com/de/catalog/product/plastic-cyclone-2/#part-225-69) |
| **MDHS 14/4** / General inhalable or respirable dusts by gravimetric analysis (total inhalable) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf) | Aktiv (Pumpe) | IOM with GF filter | GR | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-58F](https://analyt-mtc.com/de/catalog/product/glass-fibre-depth-filters-2/#part-225-58f) |
| **NIOSH 7013** / Aluminium & compounds by AAS / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7013.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **NIOSH 7013** / Aluminium & compounds by AAS / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7013.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette (or Solu-CAP cassette) | AA-F | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-8517](https://analyt-mtc.com/de/catalog/product/cassette-inserts-2/#part-225-8517) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **NIOSH 7300** / Elements by ICP (Nitric/perchloric acid ashing) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7300.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter (or Solu-CAP cassette) or 5µm PVC filter in 37mm cassette | ICP-AES | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-8517](https://analyt-mtc.com/de/catalog/product/cassette-inserts-2/#part-225-8517) / [225-5-37-P](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-8408](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-8408) |
| **NIOSH 7300** / Elements by ICP (Nitric/perchloric acid ashing) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7300.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter or 5µm PVC filter in 37mm cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-5-37-P](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **NIOSH 7301** / Elements by ICP (Aqua regia ashing) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7301.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter (or Solu-CAP cassette) or 5µm PVC filter in 37mm cassette | ICP-AES | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-8517](https://analyt-mtc.com/de/catalog/product/cassette-inserts-2/#part-225-8517) / [225-5-37-P](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-803](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-803) |
| **NIOSH 7301** / Elements by ICP (Aqua regia ashing) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7301.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter or 5µm PVC filter in 37mm cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-5-37-P](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-5-37-p) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **NIOSH 7303** / Elements by ICP (Hot block/HCl/HNO3 Digestion) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in 37mm cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **NIOSH 7303** / Elements by ICP (Hot block/HCl/HNO3 Digestion) / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in 37mm cassette (or Solu-CAP cassette) | ICP-AES | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-8517](https://analyt-mtc.com/de/catalog/product/cassette-inserts-2/#part-225-8517) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **NIOSH 7306** | Aktiv (Pumpe) |  | ICP-AES | [225-8517](https://analyt-mtc.com/de/catalog/product/cassette-inserts-2/#part-225-8517) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **OSHA ID 121** | Aktiv (Pumpe) |  | AA or AES | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **OSHA ID-121** / Metal & metalloid particulates by AAS / [Verfahrensbeschreibung (öffnet in einem neuen Tab)](https://www.osha.gov/sites/default/files/methods/osha-id121.pdf) | Aktiv (Pumpe) | 0.8µm MCE filter in cassette |  | [225-3-01](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-3-01) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) |
| **OSHA PV2121** | Aktiv (Pumpe) |  | GR | [225-8204A](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-8204a) / [225-1](https://analyt-mtc.com/de/catalog/product/cassette-and-filter-holders-2/#part-225-1) / [225-2LF](https://analyt-mtc.com/de/catalog/product/sureseal-cassette-blanks-2/#part-225-2lf) / [225-8208A](https://analyt-mtc.com/de/catalog/product/gla-5000-pvc-membrane-filters-2/#part-225-8208) / [225-105](https://analyt-mtc.com/de/catalog/product/gs-1-respirable-dust-cyclone-2/#part-225-105) / [225-3851-PW](https://analyt-mtc.com/de/catalog/product/disposable-parallel-particle-impactors-2/#part-225-3851-pw) |
| **BS ISO 15202-1: 2020** / Determination of metals and metalloids in airborne particulate matter by ICP | Aktiv (Pumpe) | IOM & foam (or cyclone) with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-772](https://analyt-mtc.com/de/catalog/product/iom-sampler-2/#part-225-772) / [225-69](https://analyt-mtc.com/de/catalog/product/plastic-cyclone-2/#part-225-69) / [225-1930](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-1930) |
| **BS ISO 15202-1: 2020** / Determination of metals and metalloids in airborne particulate matter by ICP | Aktiv (Pumpe) | IOM with 0.8µm MCE filter |  | [225-70A](https://analyt-mtc.com/de/catalog/product/haz-dust-7204-particulate-monitor-2/#part-225-70a) / [225-1930](https://analyt-mtc.com/de/catalog/product/mixed-cellulose-ester-membrane-filters-2/#part-225-1930) |

Verfahren und Grenzwerte wie von den Stellen veröffentlicht und von SKC zusammengefasst; prüfen Sie vor der Probenahme das aktuelle Verfahren und den für Sie geltenden Grenzwert. Die Grenzwerte sind die britischen (EH40), nicht die deutschen (TRGS 900).

Quelle: [SKC Ltd (UK), Hazard Search, used with SKC's permission (öffnet in einem neuen Tab)](https://www.skcltd.com/hazard-search.html); [SKC Inc. (USA), Sampling Guides, used with SKC's permission (öffnet in einem neuen Tab)](https://international.skcinc.com/sampling-guides/)