title: "Aalborg ZFM Digital Mass Flow Meter — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/zfm-digital-mass-flow-meter/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/zfm-digitaler-massendurchflussmesser/
  en: https://analyt-mtc.com/catalog/product/zfm-digital-mass-flow-meter/
  fr: https://analyt-mtc.com/fr/catalog/product/zfm-digital-mass-flow-meter-2/
---

![ZFM digital mass flow meter, 3D view](https://analyt-mtc.com/media/ZFM17A-VAL6-A2_3D.png)

1 / 3

Aalborg

# ZFM digital mass flow meter

Aalborg ZFM digital mass flow meter with high accuracy, in aluminum or stainless steel, for thermal gas flow measurement

Documents

[Aalborg ZFM Digital Mass Flow Meter — Technical data sheet · Rev. 2](https://analyt-mtc.com/documents/zfm-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/zfm-spec-sheet-en.md)) [Aalborg ZFM Digital Mass Flow Meter — Operating manual · Rev. 2](https://analyt-mtc.com/documents/zfm-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/zfm-manual-en.md))

The Aalborg ZFM is a compact digital mass flow meter that measures the flow rates of gases. Using thermal mass flow metering, it offers accuracy and high cost efficiency: ±(0.5% RD + 0.2% FS) based on actual calibration (at calibration temperature and pressure), with a repeatability of ±0.15% of full scale. Models are available in aluminum or stainless steel. It is part of the [thermal mass flow meters](https://analyt-mtc.com/catalog/thermal-mass-flow-meters/) range.

## How do I change the gas type and flow range of a ZFM?

Running the free “ZFM Configuration Utility” software, the user can select different gas types and flow ranges on-site without disconnecting, within a few minutes.

## How does a ZFM lower ownership costs?

These meters facilitate lower ownership costs by employing fewer units for multiple applications and saving on the cost of calibrations.

## Which outputs, pressure and fittings does the ZFM digital thermal mass flow meter have?

-   Outputs: linear 0-5 Vdc (3000 ohms min load impedance), linear 0-10 Vdc (5000 ohms min load impedance) and linear 4-20 mA (500 ohms maximum loop resistance).
-   Gas pressure: max. 68.9 bar(g), optimal pressure 1.7 bar(g).
-   Materials: aluminum models use anodized aluminum, brass, 316 stainless steel and Viton® O-rings; stainless steel models use 316 stainless steel and Viton® O-rings.
-   Connections: 1/4″ compression fittings; optional 1/4″, 3/8”, 6 mm compression fittings or 1/4″ VCR.

Accessories include a power supply 230VAC Europe plug 24Vdc (PS-ZFM-230EU-4) and a USB to RS232 converter (35782).

| Parameter | Value |
| --- | --- |
| **Accuracy** | ±(0.5% RD + 0.2% FS) based on actual calibration (at calibration temperature and pressure). |
| **Calibrations** | Performed at standard conditions 101.4 kPa and 21.1 °C unless otherwise requested or stated. |
| **Repeatability** | ±0.15% of full scale. |
| **Response Time** | 2 secondes to within +/-2% of flow rate, over 25% to 100% full scale |
| **Gas Temp. & ambient Temp.** | Gas temp & Ambient temp (0°C to 50°C). |
| **Output signals** | Linear 0-5 Vdc (3000 ohms min load impedance) / Linear 0-10 Vdc (5000 ohms min load impedance) / Linear 4-20 mA (500 ohms maximum loop resistance) / Maximum noise 10mV peak to peak (for 0-5 Vdc output) |
| **Gas pressure** | Max. 68.9 bar(g). Optimal pressure 1.7 bar(g). |
| **Materials** | Aluminum Models: Anodized aluminum, brass, 316 stainless steel, Viton® O-rings. / Stainless Steel Models: 316 stainless steel, Viton® O-rings. / Optional O-ring Materials: Buna-N® , EPR® (Ethylene Propylene), or Kalrez®. |
| **Connections** | 1/4″ compression fittings. / Optional: 1/4″, 3/8”, 6 mm compression fittings or 1/4″ VCR. |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| ZFM power supply 230VAC Europe plug 24Vdc with DC jack power adapter. | **PS-ZFM-230EU-4** |  |  |
| USB to RS232 converter. | **35782** |   ![ZFM digital mass flow meter](https://analyt-mtc.com/illustrations/accessories/acc-rs232.webp) |  |
| USB to 8x RS232 converter. | **USB-RS232** |   ![ZFM digital mass flow meter](https://analyt-mtc.com/illustrations/accessories/acc-rs232-8x.webp) |  |
| Universal Baseplate : / A universal bench top stand commonly used with our flowmeters, controllers or rotameters. | **35780** |   ![ZFM digital mass flow meter](https://analyt-mtc.com/illustrations/accessories/acc-35780.webp) |  |
| Pelicase for maximum safety during transport | **1200-000-110E** |   ![ZFM digital mass flow meter](https://analyt-mtc.com/illustrations/accessories/acc-pc-1400-001-110e-1.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=ZFM%20digital%20mass%20flow%20meter)