---
title: "Aalborg XFM Digital Mass Flow Meter — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/xfm/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/xfm-2/
  en: https://analyt-mtc.com/catalog/product/xfm/
  fr: https://analyt-mtc.com/fr/catalog/product/xfm-3/
---

![XFM, 3D view](https://analyt-mtc.com/media/XFM47S-VDL6-A2_3D.png)

Aalborg

# XFM

Aalborg XFM mass flow meter: low priced aluminum or stainless steel digital thermal mass flow meters

Documents

[Aalborg XFM Digital Mass Flow Meters — Technical data sheet · Rev. 2](https://analyt-mtc.com/documents/xfm-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/xfm-spec-sheet-en.md)) [Aalborg XFM Digital Mass Flow Meters — Operating manual · Rev. 2](https://analyt-mtc.com/documents/xfm-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/xfm-manual-en.md))

The Aalborg XFM is a compact digital thermal mass flow meter that measures the flow rates of gases. Using thermal mass flow metering, it offers accuracy of +/- 1.0% full scale at calibration temperature and pressure, and can store calibration for up to 10 different gases. It can be configured for flow ranges from 5 smL/min to 1000 sL/min N2. It is part of the [thermal mass flow meters](https://analyt-mtc.com/catalog/thermal-mass-flow-meters/) range.

## What does an XFM digital thermal mass flow meter include?

-   High and low flow alarm
-   Programmable flow totalizer
-   Automatic zero adjustment
-   2 relay outputs
-   Selectable 0-5 Vdc/4-20 mA analog outputs
-   Optional 2×16 characters LCD display

## How does the XFM communicate: RS-232, RS-485 or Profibus DP?

The meters offer a digital interface with RS-232 or RS-485 communication protocols (optional Profibus DP). Data include flow, CPU temperature, auto zero, totalizer and alarm settings, gas table, conversion factors and engineering units selection, dynamic response compensation and linearization table adjustment.

Accessories include a USB to RS232 adapter (35782), a USB to RS232 adapter with 8x ports (USB-RS232) and an optional power supply / cable assembly 230VAC EU plug 12Vdc: PS-XFM-230EU-2 (no support for analog interface and relays output) or PS-XFM-230EU-2-A (with support for analog interface and relays output).

## Aluminum or stainless steel XFM: which fittings and materials?

Aluminum models use anodized aluminum, brass, 316 stainless steel and Viton® O-rings. Stainless steel models use 316 stainless steel and Viton® O-rings. Optional O-ring materials are Buna-N®, EPR® (Ethylene Propylene) or Kalrez®.

The meters connect to the process with 1/4”, 3/8”, 1/2” compression fittings and 3/4” FNPT fittings. Optional fittings are available. Gas pressure is max. 34.5 barg, with an optimal pressure of 1.7 barg. They can be used as benchtop units or mounted with screws in the base.

| Parameter | Value |
| --- | --- |
| **Accuracy** | +/- 1.0% full scale at calibration temperature and pressure. |
| **Calibrations** | Performed at standard conditions (1013 hPa) & (21.11°C). |
| **Repeatability** | 0.15% of full scale. |
| **Response Time** | 2 secondes to within +/-2% of flow rate, over 25% to 100% full scale |
| **Gas Temp. & ambient Temp.** | Gas temp (0°C to 50°C). Ambient temp (-10°C to 50°C). |
| **Output signals** | Linear 0-5 Vdc, and 4-20mA 0-500 Ohms max loop resistance. |
| **Gas pressure** | Max. 34.5 barg. / Optimal pressure 1.7 barg. |
| **Materials** | Aluminum Models: Anodized aluminum, brass, 316 stainless steel, Viton® O-rings. / Stainless Steel Models: 316 stainless steel, Viton® O-rings. / Optional O-ring Materials: Buna-N® , EPR® (Ethylene Propylene), or Kalrez® |
| **Connections** | XFM 07: 1/8″ compression fittings. Optional: 1/4″ compression fittings. / XFM 17: 1/4″ compression fittings. Optional: 1/8″, 3/8”, 6 mm compression fittings, 1/4″ VCR. / XFM 37: 1/4″ compression fittings. Optional: 3/8″, 6 mm compression fittings, 1/4″ VCR. / XFM 47: 3/8″ compression fittings. / XFM 57: 3/8″ compression fittings / XFM 67: 1/2″ compression fittings. / XFM 77: 3/4″ FNPT. Optional: 3/4″ compression fittings. |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Power Supply / cable assembly 230VAC EU PLUG 12Vdc with 6 feet long communication interface branch stripped ends (no support for analog interface and relays output). (Optional). | **PS-XFM-230EU-2** |  |  |
| Power Supply / cable assembly 230VAC EU PLUG 12Vdc with 6 feet long communication interface branch stripped ends with support for analog interface and relays output. (Optional). | **PS-XFM-230EU-2-A** |  |  |
| USB to RS232 adapter | **35782** |   ![XFM](https://analyt-mtc.com/illustrations/accessories/acc-rs232.webp) |  |
| USB to RS232 adapter (8x ports) | **USB-RS232** |   ![XFM](https://analyt-mtc.com/illustrations/accessories/acc-rs232-8x.webp) |  |
| Universal Baseplate : / A universal bench top stand commonly used with our flowmeters, controllers or rotameters. | **35780** |   ![XFM](https://analyt-mtc.com/illustrations/accessories/acc-35780.webp) |  |
| Pelicase for maximum safety during transport | **1200-000-110E** |   ![XFM](https://analyt-mtc.com/illustrations/accessories/acc-pc-1400-001-110e-1.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=XFM)
