title: "XAD-2, XAD-4 and XAD-7 sorbent tubes — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/xad-sorbent-tubes/
  en: https://analyt-mtc.com/catalog/product/skc-xad-sorbent-tubes/
---

![XAD Sorbent Tubes](https://analyt-mtc.com/illustrations/skc-xad-sorbent-tubes.webp)

SKC

# XAD Sorbent Tubes

XAD-2 sorbent tubes hold hydrophobic XAD resin, used to adsorb soluble organic compounds

Documents

[SKC Sorbent Sample Tube 226-97 — Instructions for use · Rev. 1](https://analyt-mtc.com/documents/skc-xad-sorbent-tubes-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-xad-sorbent-tubes-instructions-en.md)) [SKC sampling for UK (HSE) methods — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-sorbent-tubes-hse-methods-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-sorbent-tubes-hse-methods-reference-en.md)) [SKC sampling for NIOSH, OSHA, EPA and ASTM methods — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-sorbent-tubes-us-methods-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-sorbent-tubes-us-methods-reference-en.md)) [SKC ULTRA Passive Sampler — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-ultra-sampler-selection-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-ultra-sampler-selection-reference-en.md))

XAD-2 sorbent tubes hold XAD® resin, a hydrophobic organic porous polymer used to adsorb soluble organic compounds. The same page lists XAD-4 and XAD-7 tubes.

## Which XAD-2 sorbent tube sizes are available?

The XAD-2 table lists tubes by OD x length in mm. Plain XAD-2 tubes include 226-30-05 and 226-30-04, both 8 x 110 with two sections. Other entries combine XAD-2 with PUF, a filter or Anasorb CSC, or use other sizes. For XAD-4 and XAD-7 see their own tables on this page.

## Are there coated XAD tubes?

Many variants are coated. The table lists XAD-2 tubes coated with 2-hydroxymethyl piperidine, di-n-butylamine, naphthylisocyanate, naphthylisothiocyanate, octanoic acid or p-anisidine, and XAD-7 tubes coated with NBD chloride or phosphoric acid. Tubes marked † have a limited shelf-life; refrigerator/freezer storage may be required. Contact us for more information.

## Which XAD tubes include a filter or foam?

XAD-2/Glass Fibre Filter (OVS), XAD-2/Quartz Filter (OVS) and XAD-7/Glass Fibre Filter (OVS) tubes use an OVS Tube Holder; do not use an adjustable low flow holder. For other OVS tubes, see [OSHA Versatile Sampler (OVS) Tubes](https://analyt-mtc.com/catalog/product/skc-osha-versatile-sampler-ovs-tubes/). PUF/XAD-2/PUF entries pair the resin with polyurethane foam; see [Polyurethane Foam (PUF) Tubes](https://analyt-mtc.com/catalog/product/skc-polyurethane-foam-puf-tubes/).

To select a tube for a specific compound refer to the [SKC Sampling Guides](https://www.skcltd.com/knowledge-library/sampling-methods.html) or use our [SKC online Hazard Database](https://www.skcltd.com/hazard-search.html)

Other sorbents are listed under [Sorbent tubes](https://analyt-mtc.com/catalog/sorbent-tubes/).

| Sorbent (coating) | Size (mm) ODxLength | Sections | Sorbent (mg) | Ends | Tube Cover | Separators | Pack Size | Part Number |  |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| PUF/XAD-2/PUF | 22 x 100 | 3 | 3cm/1500mg/3cm | GO | P | None | Each | **226-143** |  |
| PUF/XAD-2/PUF | 65 x 125 | 3 | 5mm/10gm/25mm | GO | – | None | Each | **226-129** |  |
| XAD-2 | 8 x 110 | 2 | 150/75 | GS | B | WWW | 50 | **226-30-05** |  |
| XAD-2 | 7 x 70 | 2 | 80/40 | GS | B | WWW | 50 | **226-30** |  |
| XAD-2 | 8 x 110 | 2 | 100/30 | GS | B | WWW | 50 | **226-30-03** |  |
| XAD-2 | 8 x 110 | 2 | 100/50 | GS | B | WWW | 50 | **226-30-04** |  |
| XAD-2 | 8 x 110 | 2 | 400/200 | GS | B | WWW | 50 | **226-30-06** |  |
| XAD-2 (_2-hydroxymethyl piperidine_) | 6 x 70 | 2 | 45/23 | GS | A | WWW | 20 | **226-54 †** |  |
| XAD-2 (_2-hydroxymethyl piperidine_) | 6 x 110 | 2 | 120/60 | GS | B | WWW | 20 | **226-118 †** |  |
| XAD-2 (_2-hydroxymethyl piperidine_) | 8 x 110 | 2 | 450/225 | GS | B | WWW | 20 | **226-27 †** |  |
| XAD-2 (_2-hydroxymethyl piperidine_) | 6 x 110 | 2 | 150/75 | GS | B | WWW | 20 | **226-117 †** |  |
| XAD-2 (_di-n-butylamine_) | 8 x 110 | 2 | 400/200 | GS | B | WWW | 20 | **226-153 †** |  |
| XAD-2 (_naphthylisocyanate_) | 8 x 110 | 2 | 200/100 | GS | B | WWW | 20 | **226-214** |  |
| XAD-2 (_naphthylisothiocyanate_) | 6 x 70 | 2 | 80/40 | GS | A | WWW | 50 | **226-30-18** |  |
| XAD-2 (_octanoic acid_) | 6 x 70 | 2 | 100/50 | GS | A | WWW | 50 | **226-23** |  |
| XAD-2 (_p-anisidine_) | 8 x 110 | 2 | 200/100 | GS | B | WWW | 20 | **226-213** |  |
| XAD-2 (_p-anisidine_) | 8 x 110 | 2 | 100/50 | GS | B | WWW | 20 | **226-30-07 †** |  |
| XAD-2/Glass Fibre Filter (OVS) | 13 to 8 x 75 | 2 | 270/140 | GO | V | FFGT | 10 | **226-30-16 \*** |  |
| XAD-2/Glass Fibre Filter (OVS) | 13 to 8 x 75 | 2 | 270/140 | GO | V | FFGT | 50 | **226-30-16A \*** |  |
| XAD-2/Quartz Filter (OVS) | 13 to 8 x 75 | 2 | 270/140 | GO | V | FFQT | 50 | **226-58A \*** |  |
| XAD-2/Quartz Filter (OVS) | 13 to 8 x 75 | 2 | 270/140 | GO | V | FFQT | 10 | **226-58 \*** |  |
| XAD-2/XAD-2/Anasorb CSC | 8 x 110 | 3 | 50/100/150 | GS | B | WWWW | 50 | **226-192** |  |
| XAD-2 / XAD-2 / (Set of 2 tubes) | 10 x 110 / 10 x 110 | 1 / 1 | 600 / 300 | GS / GS | D | WW / WW | 10 / Sets | **226-3002A** |  |

| Sorbent (coating) | Size (mm) ODxLength | Sections | Sorbent (mg) | Ends | Tube Cover | Separators | Pack Size | Part Number |  |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| XAD-4 | 6 x 70 | 1 | 120 | GS | A | WW | 20 | **226-170** |  |
| XAD-4 | 8 x 150 | 2 | 400/200 | GS | C | WWW | 20 | **226-175** |  |
| XAD-4 | 7 x 70 | 2 | 80/40 | GS | B | WWW | 50 | **226-93** |  |

| Sorbent (coating) | Size (mm) ODxLength | Sections | Sorbent (mg) | Ends | Tube Cover | Separators | Pack Size | Part Number |  |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| XAD-7 | 6 x 70 | 2 | 60/30 | GS | A | WWW | 50 | **226-94** |  |
| XAD-7 | 6 x 110 | 2 | 100/50 | GS | B | WWW | 50 | **226-95** |  |
| XAD-7 | 8 x 110 | 2 | 175/175 | GS | B | WWW | 20 | **226-211** |  |
| XAD-7 (_\[NBD\] Chloride_) | 8 x 110 | 2 | 100/50 | GS | B | WWW | 50 | **226-96** |  |
| XAD-7 (_Phosphoric acid_) | 6 x 70 | 2 | 80/40 | GS | A | WWW | 50 | **226-98** |  |
| XAD-7 (_specially cleaned_) / XAD-7 (2 tubes) / Set of 3 tubes | 8 x 110 / 8 x 110 | 1 / 1 | 175 / 175 | GS / GS | – | WGW / WW | 20 / Sets | **226-97** |  |
| XAD-7/Glass Fibre Filter (OVS) | 13 to 6 x 62 | 1 | 300 | GO | V | WGT | 50 | **226-194** |  |
| XAD-7/Glass Fibre Filter (OVS) | 13 to 8 x 75 | 2 | 200/100 | GO | V | FFGT | 50 | **226-57A** |  |
| XAD-7/Glass Fibre Filter (OVS) | 13 to 8 x 75 | 2 | 200/100 | GO | V | FFGT | 10 | **226-57** |  |

[SKC Sorbent Sample Tube 226-97 — Instructions for use · Rev. 1](https://analyt-mtc.com/documents/skc-xad-sorbent-tubes-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-xad-sorbent-tubes-instructions-en.md)) [SKC sampling for UK (HSE) methods — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-sorbent-tubes-hse-methods-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-sorbent-tubes-hse-methods-reference-en.md)) [SKC sampling for NIOSH, OSHA, EPA and ASTM methods — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-sorbent-tubes-us-methods-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-sorbent-tubes-us-methods-reference-en.md)) [SKC ULTRA Passive Sampler — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-ultra-sampler-selection-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-ultra-sampler-selection-reference-en.md)) [SKC VOC Chek 575 Passive Samplers — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-voc-chek-575-sampler-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-voc-chek-575-sampler-reference-en.md))

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=XAD%20Sorbent%20Tubes)