---
title: "SKC Vac-U-Chamber air sample box — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/skc-vac-u-chamber/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/skc-vac-u-chamber-2/
  en: https://analyt-mtc.com/catalog/product/skc-vac-u-chamber/
---

![SKC Vac-U-Chamber](https://analyt-mtc.com/illustrations/skc-vac-u-chamber.webp)

SKC

# SKC Vac-U-Chamber

The SKC Vac-U-Chamber is a rigid air sample box that fills sample bags directly with the negative pressure of most personal air sample pumps.

Documents

[SKC Vac-U-Chamber — Operating manual · Rev. 2](https://analyt-mtc.com/documents/skc-vac-u-chamber-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-vac-u-chamber-manual-en.md)) [SKC Sample Bags — Reference guide · Rev. 2](https://analyt-mtc.com/documents/skc-sample-bags-reference-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-sample-bags-reference-en.md))

The SKC Vac-U-Chamber is a rigid air sample box that allows sample bags to be filled directly by using negative pressure provided by most personal air sample pumps. It allows direct filling of SKC air sample bags. Because the sample does not pass through the pump, both pump and sample contamination are eliminated: the sample contacts only inert tubing and bag, and all surfaces in contact with the sample are constructed of inert materials.

The rigid, airtight, heavy-duty case will not collapse under vacuum. The sample line extends from the contaminant source through the case to the bag. The chamber belongs to the [Sample Bags](https://analyt-mtc.com/catalog/sample-bags/) range.

## How does the Vac-U-Chamber fill a sample bag?

The Vac-U-Chamber is equipped with three ¼ inch OD fitting ports for inflating sample bags:

-   Sample inlet port – for connecting to the sample line or gas source
-   Purge port – for purging the air prior to sampling or when preparing the bag for a standard
-   Vacuum port – for inflating a bag

An air sample bag is connected to the inside sample inlet port and the chamber is closed, providing an airtight seal. An air sample pump is connected to the outside vacuum outlet port. When activated, the pump evacuates air from inside the chamber, and the sample bag inflates as a result of the interior pressure drop. This pneumatic technique lets the air sample enter the bag directly without passing through the pump, which protects the pump from sample contaminants and the sample from pump contaminants.

## Which Vac-U-Chamber size fits which sample bag?

Four sizes are available. Each chamber is supplied without pump.

-   Small, 231-940: for 1 L sample bags, 305 x 229 x 127 mm, polypropylene fittings
-   Large, 231-939: for 8 L sample bags, 483 x 356 x 198 mm, stainless steel fittings
-   Extra-large, 231-944: for 10 L sample bags, 740 x 460 x 265 mm, polypropylene fittings
-   Jumbo, 231-946: for 25 L sample bags, 784 x 660 x 394 mm, polypropylene fittings

Two kits add a pump: 224-4115MTX (large chamber) and 224-4124MTX (small chamber) each include a 224-PCMTX8 Universal sample pump, a 100-240V AC single charger, the chamber and 10 Tedlar sample bags, 8 L (232-939) in the large kit and 1 L (232-01) in the small kit.

Matching sample bags with a single polypropylene fitting, in packs of 10, are listed under accessories: [Tedlar Sample Bags](https://analyt-mtc.com/catalog/product/skc-tedlar-sample-bags/), [FlexFoil PLUS Sample Bags](https://analyt-mtc.com/catalog/product/skc-flexfoil-plus-sample-bags/) and [Standard FlexFoil Sample Bags](https://analyt-mtc.com/catalog/product/standard-flexfoil-sample-bags-2/).

## What is the Vac-U-Chamber used for?

-   Industrial VOCs
-   Indoor air quality
-   Effluent gas samples
-   Ground water testing
-   Stack sampling
-   Ventilation studies
-   Hazardous Material (HazMat) testing

| Size | Sample Bag (L) | Dimensions |  |
| --- | --- | --- | --- |
| Small | 1 | 305 x 229 x 127 mm |  |
| Large | 8 | 483 x 356 x 198 mm |  |
| Extra-Large | 10 | 740 x 460 x 265 mm |  |
| Jumbo | 25 | 784 x 660 x 394 mm |  |

| Description | Pack Size | Part Number |  |
| --- | --- | --- | --- |
| Small Vac-U-Chamber only with polypropylene fittings (supplied without pump), suitable for use with 1 L sample bags, 305x229x127 mm | Each | **231-940** |  |
| Large Vac-U-Chamber only with stainless steel fittings (supplied without pump), suitable for use with 8 L sample bags, 483x356x198 mm | Each | **231-939** |  |
| Extra-large Vac-U-Chamber only with polypropylene fittings (supplied without pump), suitable for use with 10 L sample bags, 740x460x265 mm | Each | **231-944** |  |
| Jumbo Vac-U-Chamber only with polypropylene fittings (supplied without pump), suitable for use with 25 L sample bags, 784x660x394 mm | Each | **231-946** |  |

| Description | Pack Size | Part Number |  |
| --- | --- | --- | --- |
| **Large Vac-U-Chamber Kit, includes:** / 224-PCMTX8 Universal sample pump, 100-240V AC single charger, large Vac-U-Chamber and 10 x Tedlar 8 L Sample Bags (232-939) | Each | **224-4115MTX** |  |
| **Small Vac-U-Chamber Kit, includes:** / 224-PCMTX8 Universal Sample Pump, 100-240V AC single charger, small Vac-U-Chamber and 10 x Tedlar 1 L Sample Bags (232-01) | Each | **224-4124MTX** |  |

| Description | Pack Size | Part Number |  |
| --- | --- | --- | --- |
| FlexFoil PLUS 1 L Sample Bag with single polypropylene fitting, for use with small Vac-U-Chamber (231-940) | 10 | **252-01** |  |
| Tedlar 1 L Sample Bag with single polypropylene fitting, for use with small Vac-U-Chamber (231-940) | 10 | **232-01** |  |
| FlexFoil PLUS 8 L Sample Bag with single polypropylene fitting, for use with large Vac-U-Chamber (231-939) | 10 | **252-08** |  |
| Standard FlexFoil 8 L Sample Bag with single polypropylene fitting, for use with large Vac-U-Chamber (231-939) | 10 | **262-08** |  |
| Tedlar 8 L Sample Bag with single polypropylene fitting, for use with large Vac-U-Chamber (231-939) | 10 | **232-939** |  |
| FlexFoil PLUS 10 L Sample Bag with single polypropylene fitting, for use with Extra-large Vac-U-Chamber (231-944) | 10 | **252-10** |  |
| Tedlar 10 L Sample Bag with single polypropylene fitting, for use with Extra-large Vac-U-Chamber (231-944) | 10 | **232-10** |  |
| Tedlar 25 L Sample Bag with single polypropylene fitting, for use with Jumbo Vac-U-Chamber (231-946) | 10 | **232-25** |  |
| Replacement Quick Disconnect with tubing, for use with large Vac-U-Chamber (231-939) | Each | **P231941** |  |
| Replacement Quick Disconnect Polypropylene Female Connector, for use with small Vac-U-Chamber (231-940) | Each | **P231942** |  |
| Replacement Quick Disconnect Brass Female Connector, for use with large Vac-U-Chamber (231-939) | Each | **P231943** |  |
| PTFE Tubing, 5/16 inch OD (¼ inch ID) | 3 m | **231-937** |  |
| PTFE Tubing, 5/16 inch OD (¼ inch ID | 15 m | **231-924** |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=SKC%20Vac-U-Chamber)
