# UMEX100 Passive Sampler CH2O

UMEx 100 passive sampler for formaldehyde: meets OSHA Method 1007 specifications and conforms to EU ISO 16000-4-2004 with highly selective 2,4-DNPH chemistry for easy analysis

Documents

[SKC UMEx 100 Passive Sampler — Technical data sheet · Rev. 1](https://analyt-mtc.com/documents/skc-umex-100-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-umex-100-spec-sheet-en.md)) [SKC UMEx 100 Passive Sampler for Formaldehyde — Instructions for use · Rev. 2](https://analyt-mtc.com/documents/skc-umex-100-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-umex-100-instructions-en.md))

The UMEx 100 passive sampler for formaldehyde was developed in collaboration with the National Institute of Working Life in Umea, Sweden. Constructed of tough polypropylene, the single-use UMEx 100 contains a tape treated with 2,4-dinitrophenylhydrazine (DNPH) for reliable collection of formaldehyde. It is accurate and reliable, needs no pump or training, and is part of the [Passive Samplers](https://analyt-mtc.com/catalog/passive-samplers/) range.

## How does the UMEx 100 collect formaldehyde?

Formaldehyde forms a stable DNPH-hydrazone on the tape; analysis is by solvent extraction and HPLC with UV detection, a highly sensitive and specific analysis method. Each sampler incorporates a “blank/correction” section in addition to the active sampling section, so there is no need to send extra samplers to the laboratory: sample medium and blank/correction in one unit. Samplers are provided in individual aluminiumised pouches that can be used to transport the sampler to a laboratory after sampling. The shelf-life date is printed on a label on the outside of each pouch for easy inventory management. A clip attaches the UMEx 100 to a worker’s collar for personal sampling, or it can be placed in an appropriate location for area sampling.

-   Small and unobtrusive, with a simple-to-use “on/off” sliding cover
-   Safe: no glass or chemical liquids in the sampler
-   Versatile: suitable for both workplace sampling and long term indoor air sampling
-   Economical low cost sampler

## Does the UMEx 100 meet OSHA 1007 and ISO 16000-4?

It meets specifications of OSHA Method 1007 (if sampling in an atmosphere where Formalin is the source of formaldehyde, please contact us), conforms to EU ISO 16000-4-2004 and is referenced in EPA IP-6C. It is validated by OSHA and the Swedish Institute, and its accuracy of ± 25% exceeds OSHA requirements.

## Which sampling rate and detection limit does the UMEx 100 have?

The sampling rate is 28.6 ml/min at wind velocity of 5 to 100 cm/sec for 15 minutes to 24 hours, which enhances sensitivity for 15 minute, 8 hour, and 24 hour sampling. For 1 to 7 days it is 20.4 ml/min at wind velocities < 5 cm/sec. Uptake rates are documented for 15 minute to 24 hour samples and for 7 day samples (sampling periods between 24 hours and 7 days have not been evaluated). The limit of detection is low: 2 ppb for 24 hrs and 0.2 ppb for 7 days. The Specifications tab also lists sampling rates for other aldehydes.

The sampler is designed for single use only; do not reuse it. It has a limited shelf-life of 12 months from date of manufacture at < 4°C (39.2°F) and must not be stored with food. Packs hold 10 (500-100) or 25 (500-100A) samplers.

| Parameter | Value |
| --- | --- |
| Sampling Rate | 28.6 ml/min with a RSD (Relative Standard Deviation) of 7.6% at wind velocity of 5 to 100 cm/sec for 15 minutes to 24 hours 20.4 ml/min at wind velocities < 5 cm/sec for 1 to 7 days |
| Detection Principle | Formation of stable DNPH-hydrazone in the presence of formaldehyde |
| Validation Range | 0.06 to 3.0 ppm |
| Lower Detection Limits | 15 min: 200 ppb (0.24 mg/m3) 8 hrs: 5 ppb (0.006 mg/m3) 24 hrs: 2 ppb (0.002 mg/m3) 7 days: 0.2 ppb (0.0002 mg/m3) |
| Shelf-life | 12 months from date of manufacture at < 4°C (39.2°F) |
| Capacity | 29 µg/sample |
| Analysis | Solvent extraction and analysis by HPLC (high-performance liquid chromatography) with UV detection |
| Accuracy | ± 25%, exceeds OSHA requirements |
| Storage | Before use: < 4°C (39.2°F) After use: < 4°C (39.2°F) and analyze within 3 weeks. Do not store with food. |
| Temperature Effects | No effect on sampling rate between 10 and 30°C |
| Wind Effects | No effect from 5 to 100 cm/s |
| Interferences | Large amounts of carbonyl compounds may reduce the uptake of formaldehyde Use in ozone levels <0.5 ppm |
| Dimensions | 8.6 x 2.8 x 0.89 cm |
| Weight | 10.8 g |

|  |  |  |
| --- | --- | --- |
| Compound | Sampling Rate (mL/min) |  |
| Acetaldehyde | 22.8 ‡ |  |
| Benzaldehyde | 13.5 ‡ |  |
| Butyraldehyde | 15.8 ‡ |  |
| Crotonaldehyde | 9.71 ‡ |  |
| Glutaraldehyde | 14 ‡ |  |
| Hexanaldehyde | 9.66 ‡ |  |
| Isovaleraldehyde | 15.5 ‡ |  |
| Propionaldehyde | 14 ‡ |  |
| Chloroacetaldehyde | 19.4 \*\* |  |
| Decylaldehyde | 10.4 \*\* |  |
| Heptanaldehyde | 12.8 \*\* |  |
| Nonanaldehyde | 11.6 \*\* |  |
| o-Phthaldehyde | 12.83 \*\* |  |
| o-Tolualdehyde | 12.7 \*\* |  |
| Valeraldehyde | 15.4 \*\* |  |

| Description | Pack Size | Part Number |  |
| --- | --- | --- | --- |
| UMEx 100 Passive Sampler for Formaldehyde † # and other Aldehydes. / Designed for single use only. DO NOT reuse UMEx samplers. | 10 | **500-100** |  |
| UMEx 100 Passive Sampler for Formaldehyde † # and other Aldehydes. / Designed for single use only. DO NOT reuse UMEx samplers. | 25 | **500-100A** |  |
| Treated Tape, for QC (quality control) purposes only | 50 | **P20084** |  |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Stand for Indoor Sampling | **690-302** |   ![UMEX100 Passive Sampler CH2O](https://analyt-mtc.com/illustrations/accessories/acc-690-302-3d.webp) |  |
| Shelter for Outdoor Sampling | **690-303** |   ![UMEX100 Passive Sampler CH2O](https://analyt-mtc.com/illustrations/accessories/acc-690-303-3d.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.

[Ask an engineer](https://analyt-mtc.com/contact/?ask=1&about=UMEX100%20Passive%20Sampler%20CH2O)