title: "Elemental mercury passive sampler, OSHA ID-140 — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/elemental-mercury-passive-sampler/
  en: https://analyt-mtc.com/catalog/product/skc-elemental-mercury-passive-sampler/
---

![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/skc-elemental-mercury-passive-sampler.webp)

SKC

# Elemental Mercury Passive Sampler

The SKC 520 Series elemental mercury passive sampler offers high accuracy, sensitivity and capacity for measuring mercury in the vapour phase, for OSHA Method ID-140.

Documents

[SKC Elemental Mercury Passive Sampler — Instructions for use · Rev. 2](https://analyt-mtc.com/documents/skc-mercury-passive-sampler-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-mercury-passive-sampler-instructions-en.md))

The SKC 520 Series Elemental Mercury Passive Sampler measures worker exposure levels as a Time-Weighted Average (TWA) and permits the positive analysis of elemental mercury vapour. It is designed for analysis using standard laboratory equipment, and therefore the cost per measurement is kept to an absolute minimum compared to other samplers. Validation is based on OSHA Method ID-140.

The sampler only samples elemental mercury (Hg) in the vapour phase; it does not sample elemental Hg in the particulate phase or organic mercury compounds. For sampling low levels of mercury, use a sorbent tube. It belongs to the [Passive Samplers](https://analyt-mtc.com/catalog/passive-samplers/) range.

## How does the mercury passive sampler work?

Mercury vapour enters the sampler by positive, controlled diffusion so that a known sample volume is taken for a given period of time. Mercury is completely adsorbed onto the solid sorbent. The sorbent capsule is then taken to an accredited laboratory where the sorbent is dissolved in acid and analyzed by flameless atomic absorption. The sampler holder is cleaned and reused, thereby reducing sampling costs.

Three specifications matter when choosing: a sampling rate of 0.020 L/min (20 ml/min) at 20°C and 1013 mbar, a capacity of >30 µg mercury per capsule and a limit of detection of 0.01 µg. Long-term sampling runs up to 120 hours.

## Why use the SKC 520 mercury exposure badge?

-   Extensively field tested, with validation based on OSHA Method ID-140; meets NIOSH and OSHA standards
-   Lowest cost per measurement available, thanks to the reusable capsule holder and replaceable sorbent capsule
-   Easy to use: clips to a worker’s collar or pocket, and no pump is needed
-   High accuracy and sensitivity, with positive analysis of inorganic mercury
-   The removable sorbent capsule eliminates false high readings due to contamination of the badge housing
-   No moisture or chlorine interferences: extensive field testing and chamber studies show accuracy without interference from either moisture or chlorine
-   Simple analysis using standard laboratory equipment and analytical methods

## Which parts do I order?

-   520-03: reusable capsule holder, each; 520-03A: the same holder in a pack of 5
-   520-02A and 520-02C: sorbent capsules containing Anasorb® C300, an SKC proprietary sorbent equivalent to Hydrar® and Carulite®, with replacement foams and resealable bags; packs of 10 (520-02A) and 30 (520-02C)
-   690-302: stand for indoor sampling; 690-303: shelter for outdoor sampling

| Parameter | Value |
| --- | --- |
| Background | 0.02 µg/200mg section |
| Limit of Detection | 0.01 µg |
| Capacity | \>30 µg mercury per capsule |
| Analysis | Flameless atomic absorption |
| Weight | 14 g |
| Sampling Rate | 0.020 L/min (20 ml/min) at 20°C and 1013 mbar |

| Description | Pack Size | Part Number |  |  |
| --- | --- | --- | --- | --- |
| Reusable Elemental Mercury Sampler capsule holder | Each | **520-03** |   ![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/skc-elemental-mercury-passive-sampler.webp) |  |
| Reusable Elemental Mercury Sampler capsule holder | 5 | **520-03A** |   ![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/skc-elemental-mercury-passive-sampler.webp) |  |
| Sorbent Capsules contain Anasorb® C300\* and include replacement foams and resealable bags | 10 | **520-02A** |   ![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/accessories/acc-520-02c-3d.webp) |  |
| Sorbent Capsules contain Anasorb® C300\* and include replacement foams and resealable bags | 30 | **520-02C** |   ![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/accessories/acc-520-02c-3d.webp) |  |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Stand for Indoor Sampling | **690-302** |   ![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/accessories/acc-690-302-3d.webp) |  |
| Shelter for Outdoor Sampling | **690-303** |   ![Elemental Mercury Passive Sampler](https://analyt-mtc.com/illustrations/accessories/acc-690-303-3d.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.