# Coated (Treated) Filters

SKC coated (treated) filters are reagent-coated filters preloaded in cassettes, ready to use, meeting agency method specifications and trapping aldehydes, amines and acids without impinger liquids.

Documents

[SKC Coated Filters — Instructions for use · Rev. 1](https://analyt-mtc.com/documents/skc-coated-filters-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-coated-filters-instructions-en.md))

SKC offers coated filters to meet a variety of OSHA, NIOSH, ASTM, and international agency methods. SKC coated (treated) filters are ready to use and need no assembly: they come preloaded into cassettes with end plugs and shrink bands.

## What are coated (treated) filters used for?

Some chemicals are not effectively trapped by any solid sorbent without special preparation. Chemical coating is carried out on various sorbents to trap aldehydes, nitrogen dioxide, amines and many more compounds. Coated filters make sampling reactive compounds fast and easy, and they are a convenient alternative to wet chemistry methods using impingers. Use them to collect compounds that exist as an aerosol or mist or for some higher boiling vapours.

-   Ready to use and time-saving
-   Convenient alternative to impinger wet chemistry methods, with no cumbersome collection liquids or glass
-   Economical
-   No assembly required, with end plugs and shrink bands
-   Meet agency method specifications
-   Easy personal sampling
-   Small package size for short shelf-life product

## How do you use a coated filter cassette?

1.  Unplug the lightweight cassette.
2.  Insert it into an SKC filter cassette holder, such as those under [Cassette and Filter Holders](https://analyt-mtc.com/catalog/product/cassette-and-filter-holders/).
3.  Clip the holder to a worker’s collar.
4.  Attach it to a personal sampling pump.

Flow rates are typically greater than 1 L/min and sampling times range from 15 minutes to one hour. Most coated filter samples are extracted in solvents and analysed by gas or liquid chromatography.

## Which coated filter for hydrogen peroxide or isocyanates?

The part number table lists each chemical with its method. Two examples:

-   225-9030 for hydrogen peroxide, listed for OSHA 1019 and NON 57: two 25 mm quartz filters coated with titanium oxysulphate hydrate in a 25 mm cassette, packs of 10. It also requires sorbent tube 226-193-UC or 226-199-UC for simultaneous, separate sampling of peracetic acid.
-   225-9002 for isocyanates (HDI;2,6-TDI;2,4-TDI) under OSHA 42: one glass fibre filter and cellulose support coated with 1-(2-pyridyl) piperazine. It meets the specifications of OSHA Methods 42 and 47 but contains a higher than specified loading of reagent to increase stability and shelf-life, and traps both vapour and aerosol phases. Storage below 4°C required.

Some isocyanate filters meet multiple ASTM methods; the table refers to [ISO-CHEK Cassettes](https://analyt-mtc.com/catalog/product/iso-chek-cassettes/) for these.

The methods listed are the most widely used. Coated filters have a limited shelf life and are supplied in 37 mm cassettes unless otherwise noted. The range is part of [Gas And Vapour Sampling](https://analyt-mtc.com/catalog/gas-and-vapour-sampling/).

| Chemical | Method | Filter; Coating | Pack Size | Part Number |  |
| --- | --- | --- | --- | --- | --- |
| Acetic anhydride | OSHA 82 | 2 Glass fibre filters; _1-(2-pyridyl) piperazine_ | 10 | [225-9009](https://analyt-mtc.com/media/225-9009-2.pdf) § |  |
| Acetic anhydride | OSHA 102 | 2 Glass fibre filters; _veratrylamine and di-n-octyl phthalate_ | 10 | [225-9010](https://analyt-mtc.com/media/225-9010.pdf) † |  |
| 4-Aminobiphenyl | OSHA 93 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Aniline | NIOSH 2017 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) ¥ |  |
| Arsenic, volatile compounds | OSHA ID-1006 | 1 MCE filter and plastic pad; _untreated_ and 1 cellulose support pad; _sodium carbonate_ | 10 | [225-9001](https://analyt-mtc.com/media/225-9001.pdf) |  |
| Benzidine | OSHA 65 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Bromine, chlorine | NIOSH 6011 | 1 **25 mm** PTFE pre-filter and polypropylene support; 1 **25 mm** _specially cleaned silver membrane_ and polypropylene support in **25 mm** cassette | 5 | [225-9006](https://analyt-mtc.com/media/225-9006.pdf) |  |
| Crotonaldehyde | OSHA 81 | 2 Glass fibre filters; _2,4-dinitrophenylhydrazine and phosphoric acid_ | 10 | [225-9019](https://analyt-mtc.com/media/225-9019.pdf) § |  |
| o-Dianisidine | OSHA 71 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| 3,3-Dichlorobenzidine | OSHA 65 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Diisocyanates &(HDI;2,6-TDI;2,4-TDI) | ASTM D5836 Δ / OSHA 42 | 1 Glass fibre filter and cellulose support; _1-(2-pyridyl) piperazine_ | 10 | [225-9013](https://analyt-mtc.com/media/225-9013.pdf) § † |  |
| Diisocyanates &(HDI;2,6-TDI;2,4-TDI) | OSHA 42 | 1 Glass fibre filter and cellulose support; _1-(2-pyridyl) piperazine_ | 10 | [225-9002](https://analyt-mtc.com/media/225-9002.pdf) § ‡ |  |
| Diphenylamine | OSHA 78 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Fluorides | OSHA ID-110 / NIOSH 7902 / ASTM D4765 | 1 MCE filter and cellulose pad; _sodium carbonate_ | 10 | [225-9001](https://analyt-mtc.com/media/225-9001.pdf) # |  |
| Fluorides, particulate | NIOSH 7906 | 2 Nitrocellulose filters; 1 coated with _sodium carbonate_, 1 _uncoated_ | 10 | [225-9031](https://analyt-mtc.com/media/225-9031-1.pdf) |  |
| Glutaraldehyde | OSHA 64 | 2 Glass fibre filters; _2,4-dinitrophenyl hydrazine and phosphoric acid_ | 10 | [225-9003](https://analyt-mtc.com/media/225-9003.pdf) § |  |
| Hexavalent Chromium in Chromium Plating Mist | MDHS 52/4 | 25mm Polyvinylidine Fluoride Filter; _sodium hydroxide (filters only)_ | 24 | 225-9026 |  |
| Hydrazine | OSHA 108 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9012](https://analyt-mtc.com/media/225-9012.pdf) |  |
| Hydrofluoric acid | NIOSH 7906 | 2 Nitrocellulose filters; 1 coated with _sodium carbonate_, 1 _uncoated_ | 10 | [225-9031](https://analyt-mtc.com/media/225-9031-1.pdf) |  |
| Hydrogen bromide | NIOSH 7907 | 2 Quartz filters; sulphuric acid; 1 coated with _sodium carbonate_, 1 _uncoated_ | 10 | [225-9032](https://analyt-mtc.com/media/225-9032.pdf) |  |
| Hydrogen chloride | NIOSH 7907 | 2 Quartz filters; sulphuric acid; 1 coated with _sodium carbonate_, 1 _uncoated_ | 10 | [225-9032](https://analyt-mtc.com/media/225-9032.pdf) |  |
| Hydrogen Peroxide | OSHA 1019 | 2 **25 mm** Quartz filters; _titanium oxysulphate hydrate_ in **25 mm** cassette | 10 | [225-9030 (OSHA 1019)](https://analyt-mtc.com/media/225-9030.pdf) • |  |
| Hydrogen Peroxide | NON 57 | 2 **25 mm** Quartz filters; _titanium oxysulphate hydrate_ in **25 mm** cassette | 10 | [225-9030 (NON 57)](https://analyt-mtc.com/media/225-9030N.pdf) • |  |
| Isocyanates | ASTM ∑ | 1 PTFE filter, 1 Glass filter _treated with MAMA_ / (ISO-CHEK Sampling System) | 12 | [225-9022](https://analyt-mtc.com/media/225-9022.pdf) ∑ |  |
| Isocyanates | ASTM ∑ | 1 PTFE filter, 1 Glass filter _treated with MAMA_ / (ISO-CHEK Sampling System) | 36 | [225-9022A](https://analyt-mtc.com/media/225-9022A.pdf) ∑ |  |
| Isocyanates (HDI;2,6-TDI;2,4-TDI) | ASTM D5836 Δ | 1 Glass fibre filter and cellulose support; _1-(2-pyridyl) piperazine_ | 10 | [225-9013](https://analyt-mtc.com/media/225-9013.pdf) § † |  |
| Isocyanates (HDI;2,6-TDI;2,4-TDI) | OSHA 42 ‡ | 1 Glass fibre filter and cellulose support; _1-(2-pyridyl) piperazine_ | 36 | [225-9002](https://analyt-mtc.com/media/225-9002.pdf) § ‡ |  |
| Isocyanates (HDI, MDI, TDI, IPDI, HDI-BT, HDI-IC) | OR-OSHA 1010 | 1 Glass fibre filter; _MAMA_ / **13 mm** preloaded in a **13 mm** Swinnex holder | 5 | [225-9029](https://analyt-mtc.com/media/225-9029.pdf) § ¶ |  |
| Isocyanates, organic | MDHS 25/4 (UK) | 1 **25 mm** A/E Glass filter; _methoxyphenyl piperazine (filters only)_ | 5 | [Special Order](https://analyt-mtc.com/media/225-9011.pdf) § |  |
| n-Isopropylaniline | OSHA 78 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Maleic anhydride | OSHA 86 | 2 Glass fibre filters; _veratrylamine_ | 10 | [225-9021](https://analyt-mtc.com/media/225-9021.pdf) § |  |
| Maleic anhydride | For IFV | 1 **25 mm** Glass fibre filter; _veratrylamine (filters only)_ | 10 | [225-9028](https://analyt-mtc.com/media/225-9028.pdf) § |  |
| Mercaptans / (methyl-, ethyl-, n-butyl, and phenyl-) | NIOSH 2542 / OSHA 26 | 1 Glass fibre filter; _mercuric acetate_ | 10 | [225-9007](https://analyt-mtc.com/media/225-9007.pdf) § |  |
| 4,4′-Methylene bis (2-chloroaniline) (MOCA) | OSHA 71 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Methylene bisphenyl (MDI) | OSHA 47 | 1 Glass fibre filter and cellulose support; _1-(2-pyridyl) piperazine_ | 10 | [225-9013](https://analyt-mtc.com/media/225-9013.pdf) § † |  |
| Methylene bisphenyl (MDI) | OSHA 47 | 1 Glass fibre filter and cellulose support; _1-(2-pyridyl) piperazine_ | 36 | [225-9002](https://analyt-mtc.com/media/225-9002.pdf) § ‡ |  |
| 4,4′-Methylenedianiline | OSHA 57 Ω / NIOSH 5029 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| 1-Naphthylamine, 2-naphthylamine | OSHA 93 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Nitric acid | NIOSH 2017 | 2 Quartz filters; 1 coated with _sodium carbonate_, 1 _uncoated_ | 10 | [225-9032](https://analyt-mtc.com/media/225-9032.pdf) |  |
| Nitrobenzene | NIOSH 2017 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) ¥ |  |
| Ozone | OSHA ID-214 | 2 Glass fibre filters; _nitrite-impregnated_ | 10 | [225-9014](https://analyt-mtc.com/media/225-9014.pdf) § |  |
| Peracetic Acid | OSHA PV2321 | 1 Quartz filters (R-100); _titanium oxysulphate hydrate (TiOSO4)_ preloaded in **25 mm** 2-piece clear cassette | 10 | [225-9037](https://analyt-mtc.com/media/225-9037.pdf) ♦ |  |
| Phenylenediamine (o-, m-, p-) | OSHA 87 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| Phosphine | OSHA 1003 | 1 Glass fibre filter; 1 polyester filter treated with _mercuric chloride_ | 10 | [225-9018](https://analyt-mtc.com/media/225-9018.pdf) § † |  |
| Phosphoric acid | NIOSH 7908 | 1 Quartz filter | 10 | [225-9033](https://analyt-mtc.com/media/225-9033.pdf) ♠ |  |
| Phthalic anhydride | OSHA 90 | 2 Glass Fibre filters, _veratrylamine_ | 10 | [225-9034](https://analyt-mtc.com/media/225-9034.pdf) § |  |
| Sulphur dioxide | NIOSH 6004 (modified) | 1 MCE pre-filter and support/1 cellulose filter and support; _sodium carbonate_ | 10 | [225-9005](https://analyt-mtc.com/media/225-9005.pdf) |  |
| Sulphuric acid | NIOSH 7908 | 1 Quartz filter | 10 | [225-9033](https://analyt-mtc.com/media/225-9033.pdf) ♠ |  |
| 2,4-Toluendiamine | OSHA 65 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| 2,6-Toluendiamine | OSHA 65 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| o-Tolidine | OSHA 71 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| o-Toluidine | NIOSH 2017 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) ¥ |  |
| Toluidine / (o-, m-, p-) | OSHA 73 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |
| 1,3,5-Triglycidyl isocyanurate (TGI) | OSHA PV2055 | 1 Glass fibre filter; _hydrobromic acid_ | 10 | [225-9027](https://analyt-mtc.com/media/225-9027.pdf) |  |
| Valeraldehyde | OSHA 85 | 3 Glass fibre filters; _2,4-dinitrophenylhydrazine and phosphoric acid_ | 10 | [225-9020](https://analyt-mtc.com/media/225-9020.pdf) § |  |
| m-Xylenediamine (m-XDA, p-XDA) | OSHA 105 | 2 Glass fibre filters; _sulphuric acid_ | 10 | [225-9004](https://analyt-mtc.com/media/225-9004.pdf) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.