title: "AirChek ESSENTIAL Pump, 5–5000 ml/min — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/skc-airchek-essential-pump/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/airchek-essential-pump/
  en: https://analyt-mtc.com/catalog/product/skc-airchek-essential-pump/
---

![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/skc-airchek-essential-pump.webp)

SKC

# AirChek ESSENTIAL Pump

AirChek Essential Pump with Li-Ion battery: a low-price sample pump with touch keypad and a flow range of 5 to 5000 ml/min for dust and vapour sampling.

Documents

[SKC AirChek Essential and Essential+ Sample Pumps — Technical data sheet · Rev. 1](https://analyt-mtc.com/documents/skc-airchek-essential-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-spec-sheet-en.md)) [SKC AirChek Essential Sample Pump — Operating manual · Rev. 2](https://analyt-mtc.com/documents/skc-airchek-essential-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-manual-en.md)) [SKC Impinger Holders 225-20 for AirChek TOUCH Series Pumps — Instructions for use · Rev. 2](https://analyt-mtc.com/documents/skc-double-impinger-holder-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-double-impinger-holder-instructions-en.md)) [SKC AirChek Essential and Essential+ Sample Pumps — Quick start guide · Rev. 1](https://analyt-mtc.com/documents/skc-airchek-essential-quick-guide-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-quick-guide-en.md))

The SKC AirChek Essential pump is a low-price, simple-operation sample pump with a touch keypad; no operating manual needed. It samples from 5 to 5000 ml/min and sits in the range of [air sampling pumps](https://analyt-mtc.com/catalog/air-sampling-pumps-up-to-5-l-min/).

-   Compact, lightweight design
-   Low Price
-   Ultra-quiet
-   Large LCD with protective screen cover and screen lock-out feature

## What flow range does the AirChek Essential cover?

The extended flow range of 5 to 5000 ml/min is suitable for dust sampling and vapour sampling. Flow ranges from 1000 to 5000 ml/min, and from 5-500 ml/min with the low flow adaptor. Constant flow compensation keeps the flow within ±5%, and high back pressure compensation works up to 50 inches water at 2 L/min.

## How long does the AirChek Essential Li-ion battery run?

The powerful Li-ion battery gives long run times, over 40 hours. The specifications give a minimum of 40 hours at 2000 ml/min and 15 hours at 5000 ml/min. Charging takes approximately 3 hours. The pump needs a charging cradle and power supply; the specifications list intrinsic safety when it is used with SKC battery pack model P75718.

## What does the AirChek Essential kit include?

The pump comes with a Li-Ion battery pack, instruction manual and mini screwdriver kit. Kits add a charging cradle, power supply and Tygon tubing in a carry case, as a basic, dust sampling, vapour sampling or combined kit, for one pump or five. For a colour touchscreen, see the [AirChek TOUCH Pump](https://analyt-mtc.com/catalog/product/skc-airchek-touch-pump/).

| Parameter | Value |
| --- | --- |
| Flow System | – Flow range: 1000 to 5000 ml/min, 5-500 ml/min with low flow adaptor – Constant flow compensation provides constant flow within ±5% for accurate air volume – Flow fault appears if flow is restricted or blocked – Auto-restart is attempted after flow fault |
| Power Supply | – Removable, rechargeable Li-ion battery pack provides 40 hours minimum run time at 2000 ml/min, 15 hours at 5000 ml/min, and up to 50 inches water back pressure – Charging Time: Approximately 3 hours, depending on battery capacity and level of discharge – On screen battery status display – Link up to 5 charging cradles using one power supply – Indefinite run time from charging cradle |
| Display | – Displays elapsed sampling time – Monochrome with locking/security option |
| Temperature Range | – Operating: 0 to 40 °C – Charging: 0 to 45 °C – Storage: -20 to 45 °C |
| Case | – Recessed connector for 1/4″ ID tubing – Durable polycarbonate case – Rubberised anti-static overmoulding – Large belt clip |
| Certification | – Intrinsic safety when used with SKC battery pack model P75718: – UL Class I, Groups A, B, C and D;Class II, Groups E, F, and G;Class III, T4 Class 1, Zone I – Aexia IIC T4 Ga; Exia IIC T4 Ga; -20 C = Ta = 45 C Ex II 1G; IECEx UL 19.0100 – DEMKO 19ATEX 2288 – RoHS compliant – CE marked – Designed to meet ISO 13137:2013 |
| Tubing | 1/4″ ID |
| Dimensions | 10.4 x 9.4 x 7.1 cm |
| Weight | 550 g |

| Description | Part Number |  |
| --- | --- | --- |
| AirChek ESSENTIAL Pump with Li-Ion battery pack, instruction manual and mini screwdriver kit, Requires charging cradle and power supply; see kits or cradles below | **220-3000** |  |

| Description | Part Number |  |
| --- | --- | --- |
| **Basic Kit includes pump as described above,** / Charging Cradle, power supply with cord, Step by Step Guide, and 1 m length Tygon tubing in a durable carry case | **220-3000K** |  |
| **5-Pump Basic Kit includes 5 pumps as described above,** / 5 Standard Charging Cradles, power supply with cord, 5 x 1 m lengths of Tygon tubing and 3 Step-by-Step Guides in a durable carry case | **220-3000K5** |  |
| **Single Pump Dust Sampling Kit includes pump as described above,** / Charging Cradle, power supply with cord, Plastic IOM Multidust Sampler, 5 Multidust cassettes, IOM Foams, Calidaptor, 1 m length of Tygon tubing and Step-by-Step Guide in a durable carry case | **220-3000KP** |  |
| **5-Pump Dust Sampling Kit includes 5 pumps as described above,** / 5 Standard Charging Cradles, power supply with cord, 5 Plastic IOM Multidust Sampler, 10 Multidust cassettes, IOM Foams, Calidaptor, 5 x 1 m lengths of Tygon tubing and 3 Step-by-Step Guides in a durable carry case | **220-3000K5P** |  |
| **Single Pump Vapour Sampling Kit includes pumps as described above,** / Charging Cradle, power supply with cord, All-In-One Adjustable Tube Holder, tube cover, tube breaker, 1 m length of Tygon tubing and Step-by-Step Guide in a durable carry case | **220-3000KV** |  |
| **5-Pump Vapour Sampling Kit includes 5 pumps as described above,** / 5 Standard Charging Cradles, power supply with cord, 5 All-In-One Adjustable Tube Holders, 5 tube covers, tube breaker, 5 x 1 m lengths of Tygon tubing and 3 Step-by-Step Guides in a durable carry case | **220-3000K5V** |  |
| **Single Pump Combined Sampling Kit includes pump as described above,** / Charging Cradle, power supply with cord, plastic IOM Multidust Sampler, 5 Multidust cassettes, IOM Foams, Calidaptor, All-In-One Adjustable Tube Holder, tube cover, tube breaker, 1 m length of Tygon tubing and Step-by-Step Guide in a durable carry case | **220-3000KC** |  |
| **5-Pump Combined Sampling Kit includes 5 pumps as described above,** / 5 Standard Charging Cradles, power supply with cord, 5 plastic IOM Multidust Sampler, 10 Multidust cassettes, IOM Foams, Calidaptor, 5 All-In-One Adjustable Tube Holders, 5 tube covers, tube breaker, 5 x 1 m lengths of Tygon tubing and 3 Step-by-Step Guides in a durable carry case | **220-3000K5C** |  |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Standard Charging Cradle, requires power supply, see below | **220-800** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-220-800-3d.webp) |  |
| Single Cradle Power Supply, for use with one charging cradle | **220-600** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-220-600-3d.webp) |  |
| Multi Cradle Power Supply, for use with 2 to 5 charging cradles | **220-700** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-220-700-3d.webp) |  |
| chek-mate flowmeter, 500-5000 ml/min (recommended) | **375-0550** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-chek-mate-in-hand-500x500.webp) |  |
| Black Nylon Pump Case with adjustable waist belt and shoulder strap | **224-911** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-224-911-3d.webp) |  |
| Single Pump Case with foam cutouts for charger and accessories, and useful pockets for manuals, tubing, etc (LxWxH: 37.9 x 23.4 x 10.0 cm) | **224-97C** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-224-98-3d.webp) |  |
| Five Pump Case with foam cutouts for charger and accessories, and useful pockets for manuals, tubing, etc (LxWxH 48.0 x 35.5 x 18.0 cm) | **222-93** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-224-97a-3d.webp) |  |
| Pelican Hard-Sided Single Pump Case which is watertight, airtight, dustproof and crushproof (LxWxH: 33.9 x 29.5 x 15.2 cm) | **224-901** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-224-901-front.webp) |  |
| Pelican Hard-Sided Five Pump Case which is watertight, airtight, dustproof and crushproof. It has wheels for easy transport and a retractable handle (LxWxH 55.9 x 35.1 x 22.9 cm). | **224-914** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-224-905-3d.webp) |  |
| Waist belt, extends up to 122 cm | **224-12** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-224-12-3d.webp) |  |
| Low Flow (5 to 500 ml/min) Kit includes All-in-One Adjustable tube holder and Type A protective tube cover | **210-500** |   ![AirChek ESSENTIAL Pump](https://analyt-mtc.com/illustrations/accessories/acc-210-500-front.webp) |  |
| Replacement Battery Pack, Li-Ion | **P75718** |  |  |

[SKC AirChek Essential and Essential+ Sample Pumps — Technical data sheet · Rev. 1](https://analyt-mtc.com/documents/skc-airchek-essential-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-spec-sheet-en.md)) [SKC AirChek Essential Sample Pump — Operating manual · Rev. 2](https://analyt-mtc.com/documents/skc-airchek-essential-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-manual-en.md)) [SKC Impinger Holders 225-20 for AirChek TOUCH Series Pumps — Instructions for use · Rev. 2](https://analyt-mtc.com/documents/skc-double-impinger-holder-instructions-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-double-impinger-holder-instructions-en.md)) [SKC AirChek Essential and Essential+ Sample Pumps — Quick start guide · Rev. 1](https://analyt-mtc.com/documents/skc-airchek-essential-quick-guide-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-quick-guide-en.md)) [SKC AirChek Essential Sample Pumps — Technical note · Rev. 2](https://analyt-mtc.com/documents/skc-airchek-essential-caution-technical-note-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-airchek-essential-caution-technical-note-en.md))

## Questions about this product?

Our application engineers aim to reply within 3 business hours.