# Personal Environmental Monitor (PEM)

The Personal Environmental Monitor (PEM) is a lightweight, personal sampling device for collecting PM2.5 or PM10 particulates of 2.5 or 10 µm in indoor air.

Documents

[SKC Personal Environmental Monitor (PEM) — Operating manual · Rev. 2](https://analyt-mtc.com/documents/skc-pem-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-pem-manual-en.md))

The Personal Environmental Monitor (PEM) is a lightweight, personal sampling device that you use with a personal sampling pump to collect particulates of either 2.5 (PM2.5) or 10 µm (PM10) aerodynamic equivalent diameter in indoor air. It weighs 48 g, is referenced in EPA Method IP-10A and is available in 3 different flow rates: 2, 4 or 10 L/min.

Personal exposure is determined through gravimetric analysis for particle mass and chemical analysis for specific compounds. The monitor is small and unobtrusive, so you can connect it to a sample pump and wear it in the breathing zone.

## How does a PEM sampler work?

The PEM consists of 3 major parts: cap, impaction ring assembly, and base with after-filter. At the required flow rate, the aerosol is accelerated through a number of nozzles in the cap. Through inertia, particles larger than the 50% cut-point of the sampler impact onto a greased impaction ring, which can be discarded after sampling. Particles smaller than the 50% cut-point pass through the impactor and collect on a 37 mm after-filter.

## Which PEM do I need for PM2.5 or PM10?

Choose the cut-point by model: 2.5 µm for PM2.5 or 10 µm for PM10, each at 2, 4 or 10 L/min. The 10 µm PEM is suitable for ACGIH thoracic TLVs, including sulphuric acid and cotton dust as thoracic particulate matter. For a modular alternative, see the [Personal Modular Impactor (PMI)](https://analyt-mtc.com/catalog/product/personal-modular-impactor-pmi/).

The PEM was developed for indoor air sampling. It is not an EPA-certified instrument for ambient PM10 and PM2.5 sampling for the National Ambient Air Quality Standard (NAAQS), but outdoor use can be effective if there is no excessive wind velocity or rain at the time of sampling. More samplers are listed under [particle size-selective sampling](https://analyt-mtc.com/catalog/particle-size-selective-sampling/).

| Parameter | Value |
| --- | --- |
| Flow Rate | 2,4 or 10 L/min |
| 50% Cut-point | 2.5 or 10 µm, depending on model |
| Sample Media | 37 mm PTFE Filters |
| Tubing | 3/16 inch (4.76mm) ID |
| Dimensions | 60 x 65 x 22 mm |
| Weight | 48 g |

| Description | Pack Size | Part Number |  |  |
| --- | --- | --- | --- | --- |
| Personal Environmental Monitor (blue) for PM2.5 (2.5 µm) / Sampling Flow: 2 L/min | Each | **761-203** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-203-3d.webp) |  |
| Personal Environmental Monitor (black) for PM2.5 (2.5 µm) / Sampling Flow: 4 L/min | Each | **761-203A** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-203a-3d.webp) |  |
| Personal Environmental Monitor (red) for PM2.5 (2.5 µm) / Sampling Flow: 10 L/min | Each | **761-203B** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-203b-3d.webp) |  |
| Personal Environmental Monitor (green) for PM10 (10 µm) / Sampling Flow: 2 L/min | Each | **761-200** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-200-3d.webp) |  |
| Personal Environmental Monitor (gold) for PM10 (10 µm) / Sampling Flow: 4 L/min | Each | **761-200A** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/personal-environmental-monitor-pem.webp) |  |
| Personal Environmental Monitor (bronze) for PM10 (10 µm) / Sampling Flow: 10 L/min | Each | **761-200B** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-200b-3d.webp) |  |

| Description | Pack Size | Part Number |  |  |
| --- | --- | --- | --- | --- |
| Calibration Cap | Each | **761-202** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-202-3d.webp) |  |
| After-filter, 37 mm (2 µm pore PTFE ‡† filter with PMP support ring) | 50 | **225-1709** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-225-16xx-3d.webp) |  |
| Clamping Device, ensures that the nozzle cap is clamped parallel to the base | Each | **761-201** |   ![Personal Environmental Monitor (PEM)](https://analyt-mtc.com/illustrations/accessories/acc-761-201-3d.webp) |  |