title: "IFV Pro sampler for particles and vapour — Analyt-MTC"
url: https://analyt-mtc.com/catalog/product/ifv-pro-sampler/
lang: en
alternates:
  de: https://analyt-mtc.com/de/catalog/product/ifv-pro-sampler-2/
  en: https://analyt-mtc.com/catalog/product/ifv-pro-sampler/
---

![IFV Pro Sampler](https://analyt-mtc.com/illustrations/ifv-pro-sampler.webp)

SKC

# IFV Pro Sampler

The IFV Pro sampler simultaneously and efficiently collects contaminants in both the particle and vapour phase, such as pesticides, PAHs, organic acids and explosives.

Documents

[SKC IFV Pro Sampler — Technical data sheet · Rev. 2](https://analyt-mtc.com/documents/skc-ifv-pro-spec-sheet-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-ifv-pro-spec-sheet-en.md)) [SKC IFV Pro Sampler — Operating manual · Rev. 2](https://analyt-mtc.com/documents/skc-ifv-pro-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-ifv-pro-manual-en.md))

The SKC IFV (Inhalable Fraction and Vapour) Pro Sampler is used for simultaneously collecting mixed-phase contaminants such as pesticides, polyaromatic hydrocarbons (PAHs), inorganic acids, and explosives. It samples at 1 L/min, meets European Standard EN 13936 by collecting the total of vapour and aerosol exposures, and belongs to the [particle size selective sampling](https://analyt-mtc.com/catalog/particle-size-selective-sampling/) range.

## How does the IFV Pro sampler collect particles and vapour together?

Sampling mixed-phase contaminants is challenging because the vapour and aerosol distribution is constantly changing. The IFV Pro collects both phases at once:

-   The aerosol phase on a 25 mm filter, using an IOM-style inlet (see also the [IOM sampler](https://analyt-mtc.com/catalog/product/iom-sampler/)) sized for 1 L/min for true inhalable sampling
-   The vapour phase in a 8 mm OD x 110 mm length sorbent tube

## Why a 25 mm filter at 1 L/min?

IFV Pro overcomes the technical issues of competing models with an IOM-style inlet for true inhalable sampling, a 25 mm filter (instead of 13 mm filter) for lower back pressure, and use at 1 L/min to provide lower limits of detection. The recommended 1 L/min flow rate allows effective collection of both contaminant phases.

## Which filter and sorbent tube suit my compound?

Applications and media are shown in the IFV Pro Filter and Sorbent Selection Guide and in the datasheet. ACGIH has assigned a TLV with Inhalable Fraction and Vapour (IFV) designation to over 50 compounds that exert sufficient vapour pressure to be present in both particle and vapour phases, each contributing a significant portion of the dose. IFV Pro samples these compounds efficiently, as well as compounds found in mixed phases because of work activities or processes.

| Parameter | Value |
| --- | --- |
| Flow Rate | 1 L/min |
| 50% Cut-point | 100μm at 1 L/min inhalable fraction |
| Material | – Sampling Head: Stainless steel front plate and filter cassette with 10.6mm dia. inlet, aluminium clip, housing and outlet – Tube Holder: Black rubber – Protective Tube Cover: Plastic |
| Maximum Operating Temperature | 200°C, suitable for autoclaving and solvent washing |
| Filters | 25 mm glass fibre or quartz filter; or coated filter |
| Sorbent Tubes | Dependent on compound of interest (see table or datasheet below) |
| Tubing | 1/4 inch (6.25mm) ID |
| Dimensions | 21.6 x 3.17 cm |
| Weight | 68 g |
| Analysis | Gravimetric and chemical |

| Compound | Suggested Filter | Sorbent Tube |  |
| --- | --- | --- | --- |
| Acrylamide | 225-702 | 226-10-04 |  |
| Alachlor | 225-702 | 226-30-06 |  |
| Aldrin | 225-702 | 226-30-06 |  |
| Azinphos-methyl | 225-702 | 226-30-06 |  |
| Butylated hydroxytoluene | 225-702 | 226-211 |  |
| Carbaryl | 225-702 | 226-30-06 |  |
| Carbofuran | 225-702 | 226-30-06 |  |
| Chlorpyrifos | 225-702 | 226-30-06 |  |
| Clopidol | 225-702 | 226-30-06 |  |
| Coumaphos | 225-702 | 226-30-06 |  |
| Cresol, all isomers | 225-702 | 226-211 |  |
| Demeton | 225-702 | 226-30-06 |  |
| Demeton S-methyl | 225-702 | 226-30-06 |  |
| Diazinon | 225-702 | 226-30-06 |  |
| Dibutyl phosphaten | 225-702 | 226-30-06 |  |
| Dichlorvos | 225-702 | 226-30-06 |  |
| Dicrotophos | 225-702 | 226-30-06 |  |
| Dieldrin | 225-702 | 226-30-06 |  |
| Diesel fuel as total hydrocarbons | 225-702 | 226-09 |  |
| Diethanolamine | 225-702 | 226-14 |  |
| Dioxathion | 225-702 | 226-30-06 |  |
| Disulfoton | 225-702 | 226-30-06 |  |
| Endosulfan | 225-702 | 226-30-06 |  |
| 2-Ethylhexanoic acid | 225-702 | 226-10-04 |  |
| Fenamiphos | 225-702 | 226-30-06 |  |
| Fensulfothion | 225-702 | 226-30-06 |  |
| Fenthion | 225-702 | 226-30-06 |  |
| Fonofos | 225-702 | 226-30-06 |  |
| Glyoxal | 225-9036 | 226-119-7 |  |
| Malathion | 225-702 | 226-30-06 |  |
| Maleic anhydride | 225-9028 | 226-213 |  |
| Methomyl | 225-702 | 226-30-06 |  |
| Methyl demeton | 225-702 | 226-30-06 |  |
| Methyl parathion | 225-702 | 226-30-06 |  |
| Mevinphos | 225-702 | 226-30-06 |  |
| Monochloroacetic acid | 225-702 | 226-10-04 |  |
| Monocrotophos | 225-702 | 226-30-06 |  |
| Naled | 225-702 | 226-30-06 |  |
| o-Phthalodinitrile | 225-702 | 226-83 |  |
| Parathion | 225-702 | 226-30-06 |  |
| Pentachlorophenol | 225-702 | 226-211 |  |
| Phorate | 225-702 | 226-30-06 |  |
| Propoxur | 225-702 | 226-30-06 |  |
| Ronnel | 225-702 | 226-30-06 |  |
| Sulfotepp | 225-702 | 226-30-06 |  |
| Sulprofos | 225-702 | 226-30-06 |  |
| Temephos | 225-702 | 226-30-06 |  |
| 1,1,2,2-Tetrabromoethane | 225-702 | 226-10-04 |  |
| Tetraethylpyrophosphate(TEPP) | 225-702 | 226-106A |  |
| Thiram | 225-702 | 226-30-06 |  |
| Toluene-2,4-diisocyanate | 225-9035 | N/A |  |
| Toluene-2,6-diisocyanate | 225-9035 | N/A |  |
| Xylidene isomers | 225-702 | 226-10-04 |  |

| Description | Pack Size | Part Number |  |
| --- | --- | --- | --- |
| IFV Pro Sampler, includes: / sampling head (aerosol sampler body, cassette, and front plate), protective tube cover, cassette cap, cassette transport container, and black rubber tubing / _Requires 25 mm filter and sorbent tube_ | Each | **225-49** |  |
| IFV Pro Sampler Kit, includes sampler as above, and / calibration adaptor, and case / _Requires 25 mm filter and sorbent tube_ | Each | **225-49K** |  |

| Description | Pack Size | Part Number |  |  |
| --- | --- | --- | --- | --- |
| Filter Cassette, stainless steel with cap and transport container for 25 mm filter | Each | **225-4903** |  |  |
| Calibration Adaptor | Each | **225-361** |   ![IFV Pro Sampler](https://analyt-mtc.com/illustrations/accessories/acc-225-361-3d.webp) |  |

## Questions about this product?

Our application engineers aim to reply within 3 business hours.