# HAZ-DUST I Particulate Monitor

HAZ-DUST I particulate monitor: a portable survey tool that gives instantaneous readings for respirable dust on two selectable measuring ranges.

Documents

[SKC HAZ-DUST I Particulate Monitor — Operating manual · Rev. 2](https://analyt-mtc.com/documents/skc-haz-dust-i-manual-en.pdf) ([text version](https://analyt-mtc.com/documents/skc-haz-dust-i-manual-en.md))

The HAZ-DUST I particulate monitor is a portable dust survey tool with simple operation and an instantaneous, easy-to-read display. It is highly sensitive yet lightweight and rugged. It is one of our [particulate monitors](https://analyt-mtc.com/catalog/particulate-monitors/).

## What is the HAZ-DUST I used for?

Use it to identify areas with high levels of respirable dust and to evaluate dust generation and suppression. Readings are instantaneous and shown in mg/m3. Two measuring ranges are selectable: 0.01 to 200 mg/m3 and 0 to 20 mg/m3. The particle size range is 0.1 to 50 µm.

## How does the HAZ-DUST I measure dust?

It uses near-forward light scattering. Airborne particles entering the instrument pass through an infra-red light beam and scatter the light. The amount of light that reaches the detector is directly proportional to the aerosol concentration.

## What does the HAZ-DUST I offer for logging and unattended use?

The monitor operates for over 8 hours on its rechargeable battery and has a built-in battery test facility. Options:

-   a data logger, supplied with [DustComm Pro Software](https://www.skcltd.com/products2/particulate-monitors/dustcomm-pro-software.html) for data downloading, trend analysis and reporting of concentration changes over time;
-   a tripod with adjustable mounting for unattended monitoring.

If you need a gravimetric pump together with the optical sensor, see the [HAZ-DUST particulate monitor with gravimetric pump](https://analyt-mtc.com/catalog/product/haz-dust-7204-particulate-monitor/).

| Parameter | Value |
| --- | --- |
| Accuracy | ±10% to NIOSH 0600 |
| Sensing Range | 0.01 to 200 mg/m3, 0 to 20 mg/m3 |
| Display Resolution | 0.01 mg/m3, 0.1 mg/m3 |
| Particle Size Range | 0.1 to 50 µm |
| Calibration | NIOSH 0600 gravimetric reference – NIST traceable SAE fine test dust |
| Displayed Particle Concentration | Instantaneous |
| Power | Rechargeable NIMH battery |
| Operating Time | ≥8 hours |
| Charging Time | 10 to 12 hours |
| Temperature | Operating: -20 to +60°C Storage: -20 to +60°C |
| Dimensions | 23 x 7.6 x 3.8 cm |
| Weight | 600 g |

| Description | Part Number |  |
| --- | --- | --- |
| HAZ-DUST I Monitor Kit, includes: / Monitor, 110-240 V AC Charger and carry case (requires calibration with equipment, sold separately) | **770-1100** |  |

| Description | Part Number |  |  |
| --- | --- | --- | --- |
| Calibration Standard, for verifying span and optical sensor performance. A light-scattering device providing a constant value. | **770-102** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/illustrations/accessories/acc-770-102-3d.webp) |  |
| Zeroing Accessory, for pumping filtered air into the sensor for a zero reading in contaminated environments | **770-130** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/illustrations/accessories/acc-770-130-3d.webp) |  |
| Data Logger: / data storage, on-screen display of statistics and user-selectable alarm threshold, includes analogue signal cable, computer RS-232 interface cable and DustComm Pro Software on a USB Memory Stick. Dimensions: 17.8 x 8.8 x 6.3 cm (7 x 3.5 x 2.5 inches), Weight: 450 g | **770-113** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/media/770-113_3D-300x300.png) |  |
| Analogue Signal Cable for Data Logger | **770-107** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/illustrations/accessories/acc-770-107-3d.webp) |  |
| Replacement NiMH Battery Pack for Data Logger | **770-127** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/illustrations/accessories/acc-770-127-3d.webp) |  |
| Tripod Stand, adjustable stand (1 to 1.5 m) and mounting plate for unattended monitoring | **770-129** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/illustrations/accessories/acc-770-129-3d.webp) |  |
| Cleaning Kit, includes bulb, swabs and lens tissue | **770-305B** |  |  |
| AC Charger 110-240 V, can also be used to operate HAZ-DUST I for extended running time | **770-131** |  |  |
| Replacement NiMH Battery Pack for HAZ-DUST I | **770-108** |   ![HAZ-DUST I Particulate Monitor](https://analyt-mtc.com/illustrations/accessories/acc-770-108-3d.webp) |  |